Home ProductsAtomic Absorption Spectrometer

Three Lamp Flame Atomic Absorption Spectrometer Grating 1800l/Mm

Three Lamp Flame Atomic Absorption Spectrometer Grating 1800l/Mm

Three Lamp Flame Atomic Absorption Spectrometer Grating 1800l/Mm

Product Details:

Place of Origin: China
Brand Name: Macy
Certification: CE/ISO/ROHS/FDA
Model Number: AA-1800F

Payment & Shipping Terms:

Minimum Order Quantity: 1pc
Price: USD negotiable
Packaging Details: 1200x700x700mm
Supply Ability: 3weeks
Contact Now
Detailed Product Description
High Light:

flame atomic absorption spectrometer

,

1800l/Mm atomic absorption spectrometer

,

flame aa spectrometer

AA-1800F atomic absorption spectrometer (Three lamp flame method)

 

Technical parameters

1. Working conditions

1.1 Power requirements: 220V (+5% ~ -10%), 50/60 Hz; 5000VA

1.2 Environment temperature: +15℃~+35℃

1.3 relative humidity: 20 ~ 80%

 

2. Technical indicators

2.1 Optical system

2.1.1 Grating: 1800 l /mm

2.1.2 Wavelength range: 190-900nm

2.1.3 Spectral bandwidth :0.1,0.2,0.4,,1.0,2.0nm (automatic adjustable)

2.1.4 Wavelength accuracy: ≤0.15nm

Wavelength repeatability: ±0.1nm

2.1.5 Baseline stability: ≤±0.002A/30 minutes( static)

≤±0.005A/30 minutes.(dynamic)

2.1.6 Light source: ≤3 lamps automatic turret, automatic alignment

2.1.7 Power: double cathode power built-in high performance lamps

 

2.2 Flame atomizer

2.2.1 Characteristic concentration (Cu):0.015μg/mL/1%.

2.2.2 Detection limits(Cu):0.002μg/mL

2.2.3 Precision: RSD≤0.5%

2.2.4 Combustion head: metal titanium combustion head

2.2.5 Atomizer: efficient glass atomizer

2.2.6 Atomizing chamber: explosion proof corrosion resistant material spray chamber

2.2.7 Control system: automatic PC control three light brick, automatic alignment, automatic optimization and automatic ignition

2.2.8 Safety protection: with automatic safety protection function, anti temperingautomatic gas path protection, acetylene gas leakage alarm, automatic shutdown system, abnormal automatic power-off

2.2.9 Background correction: deuterium background correction: correction of the 1A background

 

2.3 Data processing

2.3.1 Measurement methods: flame method, hydride method

2.3.2 Concentration calculation method: standard curve method (1 ~ 3 times curve),automatic matching, the standard addition method

2.3.3 Repetition survey frequency: 1-99 times, calculating the average value, standard deviation and relative standard deviations are given

2.3.4 Results print: parameters print, data and graphics print, you can also export WORD, EXCEL document

2.3.5 Simple and convenient operation, lamp position rotating, automatic ignition through software operating

2.3.6 Communication interface: computer and USB interface communication

Contact Details
Macylab Instruments Inc.

Contact Person: macylab

Tel: +8615811084384

Send your inquiry directly to us (0 / 3000)