Send Message
products
PRODUCTS
Home > Products > Atomic Absorption Spectrometer > 900nm 5000VA Atomic Absorption Spectroscopy Instrument

900nm 5000VA Atomic Absorption Spectroscopy Instrument

Product Details

Place of Origin: China

Brand Name: Macy

Certification: CE/ISO/ROHS/FDA

Model Number: AA-1800C

Payment & Shipping Terms

Minimum Order Quantity: 5pcs

Price: Negotiable

Packaging Details: Carton packaging, plus a wooden

Delivery Time: Received payment,within 10 days of delivery

Payment Terms: T/T,Western Union

Supply Ability: 1000pcs/month

Get Best Price
Highlight:

900nm atomic absorption spectroscopy instrument

,

5000va atomic absorption spectroscopy instrument

,

hollow cathode lamps atomic absorption spectrometer

Product Name:
Photometer
Source Type:
Hollow Cathode Lamps
Wavelength Range:
180~900nm
Spectral Bandwidth:
0/0.2/0.4/1.0/2.0nm
Wavelength Accuracy:
≤0.15nm
Name:
900nm Atomic Absorption Spectroscopy Instrument
Product Name:
Photometer
Source Type:
Hollow Cathode Lamps
Wavelength Range:
180~900nm
Spectral Bandwidth:
0/0.2/0.4/1.0/2.0nm
Wavelength Accuracy:
≤0.15nm
Name:
900nm Atomic Absorption Spectroscopy Instrument
900nm 5000VA Atomic Absorption Spectroscopy Instrument

Pesticide ResiduesAtomic Absorption Spectrometer For Industrial Inspection​

 

 

Specifications:

Mainframe
Model: AA-1800C
Light Source: ≤6 lamps automatic turret, automatic alignment
Power Supply: 110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current: pulsed power supply
Optical System: large 1800 /mm grating ruling, full closed optical system
Wavelength Range: 180nm-900nm                  
Automatically peak find,a key opticaloptimization function
Wavelength Accuracy: ≤0.15nm
Wavelength Repeatability: ±0.1nm
Spectral Bandwidth: 0nm,0.2nm,0.4nm,1.0nm,2.0nm
(5 steps with automatic changeover)
Baseline Stability: ≤±0.002A/30 min (Static)      
≤±0.005A/30min (Dynamic)
Absorbance Range: 0-4A
Detector: imported photomultiplier tube 
Flame Analytical System
Burner Head: full titanium combustion head, 50mm or 100mm generalcombustion head
Atomization Chamber: polymer explosion-proof spray chamber
Nebulizer: atomizer efficient glass atomizer, can also be customized
Ignition Type: microcomputer control, automatic ignition
Gas Control: automatic gas control system
Detection Limits(Cu): 0.002μg/mL
Precision: RSD≤0.5%

 

 

 

Applications:

 

AA-1800C atomic absorption spectrophotometer is now widely used in scientific research,quality control,

disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and

software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples,

equipment maintenance, simple and convenient