High Resolution Double Beam Spectrophotometer Touch Screen Display For Laboratory

Product Details

Place of Origin: China

Brand Name: Macy

Certification: CE/ISO/ROHS

Model Number: UV-1800CSPC

Payment & Shipping Terms

Minimum Order Quantity: 5pcs

Price: USD4536-USD4859

Packaging Details: Carton packaging

Delivery Time: Received payment,within 10 days of delivery

Payment Terms: T/T,Western Union

Supply Ability: 1000pcs/month

Get Best Price
Highlight:

high resolution double beam spectrophotometer

,

touch screen display double beam spectrophotometer

,

uv-1800 double beam uv spectrophotometer

Product Name:
UV-Visible Spectrophotometer
Key Words:
High Resolution
Wavelength Setting:
Automatic
Wavelength Range::
190~1100nm
Spectral Bandwidth::
0.5 1 2 4 Nm
Wavelength Accuracy::
±0.3nm
Stability::
0.0005A/h(500nm Preheated)
Weight::
28kg
Band Width:
2nm
Display:
7 Inch Color Touchscreen
Product Name:
UV-Visible Spectrophotometer
Key Words:
High Resolution
Wavelength Setting:
Automatic
Wavelength Range::
190~1100nm
Spectral Bandwidth::
0.5 1 2 4 Nm
Wavelength Accuracy::
±0.3nm
Stability::
0.0005A/h(500nm Preheated)
Weight::
28kg
Band Width:
2nm
Display:
7 Inch Color Touchscreen
High Resolution Double Beam Spectrophotometer Touch Screen Display For Laboratory

 

UV-1800CSPC

 

 

Parameters:

 

Optical System: Double beam

Wavelength Range 190~1100nm

Band Width 0.5 , 1, 2, 4nm

Wavelength Accuracy ±0.3nm

Wavelength Repeatability ≤0.2nm

Photometric Accuracy ±0.3% τ

Photometric Repeatability 0.15% τ

Stray Light ≤0.05% τ (220nm NaI,360nm NaNO2)

Stability 0.001A/h@500nm

Baseline Flatness ±0.001A

Photometric Mode T,A,C,E

Wavelength Setting Automatic

Photometric Display Range -4~4A

Display Mode 10 inches touch screen LCD

Detector Import Silicon Photodiode

Light Source Import Deuterium Lamp & Tungsten Halogen Lamp

Power Requirement AC 220V/50Hz 110V/60Hz

Power 120W

Dimensions(W*D*H) 560×450×230mm

Weight 28Kg

 
 

High Resolution Double Beam Spectrophotometer Touch Screen Display For Laboratory 0

Advantages:

1. High resolution, good stability, and repeatability. Novel in appearance and easy to operate.

2. Power off maintenance: the measurement data of memory is not lost during power off.

3.LCD large screen display, menu operation interface, touch button, novel appearance and convenient operation

4. The key assembly method is adopted inside the instrument, to replace the parts without special tools, and the maintenance is convenient.

5. All set parameters and test results can be stored, and the lighting time is automatically recorded.

6. The unique dual beam and dual detector light path are used to ensure the stability of the instrument. Vertical detection optical path shortens the optical path, reduces the loss of light energy, and ensures that the instrument has high energy. The excellent performance of low noise improves the long-term stability of the instrument. Imported special light source, low power consumption, high luminous efficiency, long service life. The instrument is equipped with professional software to make your operation more convenient. It has intelligent functions such as start-on self-inspection, automatic correction wavelength and energy test to ensure that the instrument is in a stable test state every time you use it. The software is powerful and designed more humanized.

 

Exhibition:

 

High Resolution Double Beam Spectrophotometer Touch Screen Display For Laboratory 1

High Resolution Double Beam Spectrophotometer Touch Screen Display For Laboratory 2

Certificate:

High Resolution Double Beam Spectrophotometer Touch Screen Display For Laboratory 3

Our company:

High Resolution Double Beam Spectrophotometer Touch Screen Display For Laboratory 4

 

FAQ:

 

1. Why the reading is red and reach its maximum value 3.00Abs?
Probably you use the glass cuvette in UV range.

2. Why the wavelength calibration or self checking fail?
The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.
 
3. Why is the reading is not as accurate as before?
Do the wavelength calibration before testing or restore the device to its default factory settings.
 
4. Why PC software can not be installed successfully?
Close your anti-virus software on the computer and do it again.
 
5. Why the Abs value is negative(lower than zero)?
Do the blanking or change the reference sample.

 

 