Wavelength Range:
190~1100nm
Band Width:
1.8nm
Wavelength Accuracy:
±0.3nm
Photometric Accuracy:
±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
Photometric Repeatability:
±0.15% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
Stray Light:
≤0.03% τ (220nm NaI,340nm NaNO2)
Stability:
0.0005A/h@500nm
Photometric Mode:
T,A,C,E
Wavelength Setting:
Automatic
Photometric Display Range:
-4~4A
Display Mode:
6 Inches High Brightness Blue LCD
Detector:
Import Silicon Photodiode
Power Requirement:
AC220V/550Hz 110V/60Hz
Power:
120W
Wavelength Range:
190~1100nm
Band Width:
1.8nm
Wavelength Accuracy:
±0.3nm
Photometric Accuracy:
±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
Photometric Repeatability:
±0.15% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
Stray Light:
≤0.03% τ (220nm NaI,340nm NaNO2)
Stability:
0.0005A/h@500nm
Photometric Mode:
T,A,C,E
Wavelength Setting:
Automatic
Photometric Display Range:
-4~4A
Display Mode:
6 Inches High Brightness Blue LCD
Detector:
Import Silicon Photodiode
Power Requirement:
AC220V/550Hz 110V/60Hz
Power:
120W
1.8nm Macylab Double Beam Uv Visible Spectrophotometer Atomatic Absorption
Macylab factory double Beam atomatic absorption UV/Visible Spectrophotometer

 

 

 

                                                      UV-1800PC UV-V Spectrophotometer                                                       

 

UV-1800PC successful implementation of the stringent requirements of high accuracy and reliability measurement to meet the requirements of various applications that can be used in biological research, bio-industry , pharmaceutical analysis , pharmaceutical, teaching and research, environmental protection , food hygiene, clinical examination , health and epidemic prevention , and other fields .

 


Competitive Advantage:

1.A wide wavelength range, the wavelength range to meet the various requirements of the field
2.Automatic design to achieve the most simple means of measurement
3.LSI design greatly improves the stability and reliability of the system
4.Improved optimization of the optical design , import source and receiver system created a high performance and high reliability
5.Rich measurement methods , with a wavelength scan , time scan , multi-wavelength determination , multi-order derivative determination (optional ) , dual-wavelength , three-wavelength (optional ) DNA protein measurements (optional ) , and other measurement methods to meet different measurement requirements , and can be displayed directly on a 6- inch screen
6.Based on user requirements optional hole rack , manual four with stand , manual Eighth rack , automatic Eighth frame, glass stand , test tube rack , 1cm colorimetric frame , 5cm colorimetric frame , 10cm colorimetric racks
7.Measurement data can be output through the printer with USB interface
8.Can be powered down to save the measurement parameters and data , user-friendly
9.Can achieve more accurate and flexible measurement via PC control , which can meet the needs of different users


Spectrometer

Optical System Double beam
Wavelength Range 190~1100nm
Band Width 1.8nm
Wavelength Accuracy ±0.3nm
Wavelength Repeatability ≤0.1nm
Photometric Accuracy ±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
Photometric Repeatability ±0.15% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
Stray Light ≤0.03% τ (220nm NaI,340nm NaNO2)
Stability 0.0005A/h@500nm
Noise ± 0.0002A @500nm
Baseline Flatness ± 0.001A
Photometric Mode T,A,C,E
Wavelength Setting Automatic
Photometric Display Range -4~4A
Display Mode 6 inches high brightness blue LCD
Detector Import Silicon Photodiode
Light Source Import Deuterium Lamp & Tungsten Halogen Lamp
Power Requirement AC 220V/50Hz 110V/60Hz
Power 120W
Dimensions(W*D*H) 560×450×230mm
Weight 28Kg

1.8nm Macylab Double Beam Uv Visible Spectrophotometer Atomatic Absorption 0 


1.8nm Macylab Double Beam Uv Visible Spectrophotometer Atomatic Absorption 1   

          


                                                                      Application Field                                                                          1.8nm Macylab Double Beam Uv Visible Spectrophotometer Atomatic Absorption 2

                                                                            Certificate                                                                               1.8nm Macylab Double Beam Uv Visible Spectrophotometer Atomatic Absorption 3

                                                                   Company profile                                                                            

  Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader.

1.8nm Macylab Double Beam Uv Visible Spectrophotometer Atomatic Absorption 4

  Macylab Instruments Inc. operates spectroscopic instruments, such as spectrophotometers, UV-visible spectrophotometers, atomic absorption spectrometers, ultra-micro spectrophotometers, atomic fluorescence spectrophotometers, ICP inductively coupled plasma emission spectrometers. Currently, our products have been Widely used in organic chemistry, inorganic chemistry, biochemistry, medicine, environmental protection, metallurgy, petroleum, agriculture and other fields. At the same time, the company has accumulated a wealth of experience in product mechanical structure, optical design, electrical applications and software development, combined with the latest practical needs of the market, will soon launch a number of new analytical instruments.
  Macy's headquarter and production base is located in Shanghai, the marketing center in Beijing, and three R & D bases in Jiangsu, Shanghai, and Shandong. To take full advantage of the country's intellectual resources, MACY and the domestic and foreign research unit also conducted deep scientific research cooperation, will continue to put the research achievements into productivity .To better serve our customers, Macy has 12 domestic offices, tailored to meet the needs of your application solutions to improve the value of the products. At the same time continue to serve domestic users, Macy also with distribution in over 20 countries to establish a deep strategic partnership cooperation.
  Along with Macy accelerate the pace and rank among the global brand instruments, Macy increasing demands of our own, and we also hope to get the care and support of the community, Let us work and outlook together.Technology, will change because you and us.

                                                                           Exhibitions                                                                                   

1.8nm Macylab Double Beam Uv Visible Spectrophotometer Atomatic Absorption 5

1.8nm Macylab Double Beam Uv Visible Spectrophotometer Atomatic Absorption 6