Product Details

Place of Origin: China

Brand Name: Macylab

Certification: ROSH, FCC, CE, ISO9001

Model Number: UV-1900PC

Payment & Shipping Terms

Minimum Order Quantity: 1pc

Price: 8,908$

Packaging Details: container

Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability: 1000pc

Get Best Price
Highlight:

teaching uv spectrophotometer double beam

,

lab uv spectrophotometer double beam

,

research laboratory spectrophotometer

Name:
Macylab Fully Automatic Teaching Research Uv Spectrophotometer Double Beam Wavelength Range
Keyword:
Ultraviolet Visible Spectrophotometer
Weight:
28kg
Dimensions(W*D*H):
560×450×230mm
Power:
AC 220V/50Hz 110V/60Hz
Power Requirement:
120w
Light Source:
Import Deuterium Lamp & Tungsten Halogen Lamp
Detector:
Import Silicon Photodiode
Name:
Macylab Fully Automatic Teaching Research Uv Spectrophotometer Double Beam Wavelength Range
Keyword:
Ultraviolet Visible Spectrophotometer
Weight:
28kg
Dimensions(W*D*H):
560×450×230mm
Power:
AC 220V/50Hz 110V/60Hz
Power Requirement:
120w
Light Source:
Import Deuterium Lamp & Tungsten Halogen Lamp
Detector:
Import Silicon Photodiode
Macylab Fully Automatic Teaching Research Uv Spectrophotometer Double Beam Wavelength Range

Macylab Fully Automatic Teaching Research Uv Spectrophotometer Double Beam Wavelength Range

 

UV-1900PC successfully achieved the stringent requirements of high accuracy and reliability measurement to meet the reguirements of various applications that can be used in biological research, bio-industry , pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection , food hygiene, clinical examination, health and epidemic prevention and other fields.
 

 

Technical Specifications
Optional System Double beam
Optional circuit structure C-T Type Parallel double beam
Wavelength Range 190~1100nm
Band Width 0.5,1,2,4nm
Wavelength Accuracy ±0.3nm
Wavelength Repeatability 0.1nm
Photometric Accuracy ±0.3% τ(0-100%τ) ±0.002A(0~0.5A) ±0.003A(0.5A~1A)
Photometric Repeatability 0.15% τ(0-100%τ) ±0.001A(0~0.5A) ±0.0015A(0.5A~1A)
Stray Light ≤0.03% τ (220nm NaI,340nm NaNO2)
Stability 0.0005A/h@500nm
Noise ± 0.0002A @500nm
Baseline Flatness ± 0.001A
Photometric Mode T,A,C,E
Wavelength Setting Automatic
Photometric Display Range -4~4A
Display Mode 10 inches touch screenLCD
Detector Import Silicon Photodiode
Light Source Import Deuterium Lamp & Tungsten Halogen Lamp
Power Requirement AC 220V/50Hz 110V/60Hz
Power 120W
Dimensions(W*D*H) 560×450×230mm
Weight 28Kg

 

Our Advantages

Quality
1. Our products have good quality and very positive reputations in the market.
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders.
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable

 

Macylab Fully Automatic Teaching Research Uv Spectrophotometer Double Beam Wavelength Range 0

 

 

 

 

Product Features

 

1.A wide wavelength range, the wavelength range to meet the various requirements of the field.

 

2.4nm, 2nm, 1nm, 0.5nm spectral bandwidth of four customized according to user requirements can be installed to meet the stringent

requirements of the Pharmacopoeia.


3.Automatic design to achieve the most simple means of measurement.


4.SI design greatly improves the stability and reliability of the system


5.Improved optimization of the optical design , import source and receiver system created a high performance and high reliability.


6.Rich measurement methods , with a wavelength scan, time scan, multi-wavelength determination, multi-order derivative determination (optional ), dual-wavelength, three-wavelength (optional ) DNA protein measurements (optional ) , and other measurement methods to meet different measurement requirements , and can be displayed directly on a 10 inches touch screen LCD


7.Based on user requirements optional hole rack, manual four with stand manual Eighth rack , automatic Eighth frame, glass stand, test tube rack , 1cm colorimetric frame , 5cm colorimetric frame ,10cm colorimetric racks.

 

8.Measurement data can be output through the printer with USB interface.


9.Can be powered down to save the measurement parameters and data , user-friendly.