Send Message
products
PRODUCTS
Home > Products > Atomic Absorption Spectrometer > Aa-1800el Aas Atomic Absorption Spectroscopy Flame And Graphite Furnace System

Aa-1800el Aas Atomic Absorption Spectroscopy Flame And Graphite Furnace System

Product Details

Place of Origin: China

Brand Name: Macylab

Certification: CE ISO ROHS FCC FAD

Model Number: AA-1800EL

Payment & Shipping Terms

Minimum Order Quantity: 1pcs

Price: USD16376-USD24558/Set

Packaging Details: Wood Box

Delivery Time: 5-10days

Payment Terms: Western Union, MoneyGram, T/T, L/C

Supply Ability: 5000Set / year

Get Best Price
Highlight:

aa-1800el aas atomic absorption spectroscopy

,

eight lamp aas atomic absorption spectroscopy

Name:
Eight Lamp Flame/graphite Furnace Intergrated AA-1800EL Atomic Absorption Spectrophotometer
Application:
Laboratory Apparatus
Wavelength Range:
Large 185nm-900nm
Wavelength Accuracy:
±0.15nm
Wavelength Repeatability:
<0.10nm
Spectral Bandwidth:
0.1、0.2、0.4、0.7、1.0、1.4、2.0nm
Absorbance Range:
0-4A
Detector:
Imported Photomultiplier Tube
Name:
Eight Lamp Flame/graphite Furnace Intergrated AA-1800EL Atomic Absorption Spectrophotometer
Application:
Laboratory Apparatus
Wavelength Range:
Large 185nm-900nm
Wavelength Accuracy:
±0.15nm
Wavelength Repeatability:
<0.10nm
Spectral Bandwidth:
0.1、0.2、0.4、0.7、1.0、1.4、2.0nm
Absorbance Range:
0-4A
Detector:
Imported Photomultiplier Tube
Aa-1800el Aas Atomic Absorption Spectroscopy Flame And Graphite Furnace System

Aa-1800el Aas Atomic Absorption Spectroscopy Flame And Graphite Furnace System 0

                                              AA-1800EL Atomic Absorption Spectrophotometer                                                

   

    AA-1800EL atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.

    AA-1800EL atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.

 


Main features


High precision automatic optical system
1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 8 socket configuration 8 independent lamp power supply, can be respectively preheating

Polymer spray chamber
Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability

Titanium burner
Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame

Automatic analysis
It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.
The light source system 8 lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automaticwavelength scanning and searching peak


Software function
High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method

Graphite furnace temperature control
Gas dual temperature control inside and outside, 20 order linear or nonlinear heating, to ensure that the measured elements has the highest sensitivity; furnaceenriched up to 20 times, the longitudinal optically monitoring the graphite tube wall temperature, maximum temperature to 3000 degrees centigrade.

High technology index
AA-1800 atomic absorption spectrophotometer elements testsensitivity meet international best level,sensitivity of less than or equal to0.015μg/mL/1%; baseline drift is less than 0.003Abs/30m, the stability is better than 0.005Abs/4h

Background correction system
Using deuterium hollow cathode lamp advanced and self absorption background deduction of background correction, to eliminate the interference of molecular absorption of low content determination, reducing the noise emission of deuterium lampand prolongs the service life, has excellent stability. Deuterium lamp background signalfor 1A,
background correction ability > 60 times


Intelligent analysis
Greart intelligence, humanized design, flame and graphite furnace atomizer automatic switching, automatic optimization of graphite furnace atomizer, automatically set the flame height adjustment, automatic ignition, automatic optimization of the horizontal position, system automatically sets the gas flow. In the case of power failure, misoperation, acetylene leakage, the system will automatically start the safetyprotection function

Automatic sampler
Integrative design of graphite furnace, using high precision syringe, lowest in 0.5μl samples, with intelligent online dilution and concentration function.
 

 


 

Technical parameters
 

Mainframe
 

Light Source

≤8 lamps automatic turret, automatic alignment

Power Supply

110/220V (+5% ~ -10%), 60/50Hz; 5000VA

Lamp Current

pulsed power supply

Optical System

large 1800 /mm grating ruling, full closed optical system

Wavelength Range

185nm-900nm Automatically peak find,a key opticaloptimization function

Wavelength Accuracy

±0.15nm

Wavelength Repeatability

<0.1nm

Spectral Bandwidth

0.1,0.2,0.4,0.7,1.0,1.4,2.0nm (7 steps with automatic changeover)

Baseline Stability

≤±0.002A/30 min (Static) ≤±0.004A/30min (Dynamic)

Absorbance Range

0-4A


Flame Analytical System
 

Detector

imported photomultiplier tube

Burner Head

full titanium combustion head, 50mm or 100mm generalcombustion head

Atomization Chamber

polymer explosion-proof spray chamber

Nebulizer

atomizer efficient glass atomizer, can also be customized

Ignition Type

microcomputer control, automatic ignition

Gas Control

automatic gas control system

Detection Limits(Cu)

0.002μg/mL

Precision

RSD≤0.5%


Graphite Furnace Analytical System
 

Heating Mode

vertical heating

Temperature Control Method

vertical optical temperature monitoring graphite tube wall temperature

Temperature Range

room temperature to 3000ºC

The Program

automatic temperature control up to 20 order

Temperature Control

the furnace enriched up to 20 times

Characteristics Volume

0.4 × 10-12g (Cd)

Detection Limit

0.4 × 10-12g (Cd)

Precision

RSD≤2%

The Cooling Water

can choose cooling water circulation system

Safety

the graphite tube damage, water flow air pressure and other alarmtemperature overheating protection

 

 


Aa-1800el Aas Atomic Absorption Spectroscopy Flame And Graphite Furnace System 1   

          


                                                                      Application Field                                                                                 Aa-1800el Aas Atomic Absorption Spectroscopy Flame And Graphite Furnace System 2

                                                                            Certificate                                                                                      Aa-1800el Aas Atomic Absorption Spectroscopy Flame And Graphite Furnace System 3

                                                                   Company profile                                                                                     

   

Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader.

 

Aa-1800el Aas Atomic Absorption Spectroscopy Flame And Graphite Furnace System 4

                                                                           Exhibitions                                                                                      

Aa-1800el Aas Atomic Absorption Spectroscopy Flame And Graphite Furnace System 5

Aa-1800el Aas Atomic Absorption Spectroscopy Flame And Graphite Furnace System 6