Product Details
Place of Origin: CHINA
Brand Name: Macylab
Certification: ALL OF MADE IN CHINA
Model Number: AA-1800S
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: usd10000/set
Packaging Details: PE film then pur into wooden carton
Delivery Time: Within 5 days
Payment Terms: L/C, T/T, Western Union, MoneyGram
Supply Ability: 120SET/DAY
Light Source: |
6 Lamps Automatic Turret, Automatic Alignment |
Power Supply: |
110/220V (+5% ~ -10%), 60/50Hz; 5000VA |
Lamp Current: |
Pulsed Power Supply |
Optical System: |
Large 1800 /mm Grating Ruling, Full Closed Optical System |
Wavelength Range: |
190nm-900nm |
Absorbance Range: |
0-4A |
Light Source: |
6 Lamps Automatic Turret, Automatic Alignment |
Power Supply: |
110/220V (+5% ~ -10%), 60/50Hz; 5000VA |
Lamp Current: |
Pulsed Power Supply |
Optical System: |
Large 1800 /mm Grating Ruling, Full Closed Optical System |
Wavelength Range: |
190nm-900nm |
Absorbance Range: |
0-4A |
Mainframe
|
|
Model
|
AA-1800S
|
Light Source
|
≤6 lamps automatic turret, automatic alignment
|
Power Supply
|
110/220V (+5% ~ -10%), 60/50Hz; 5000VA
|
Lamp Current
|
pulsed power supply
|
Optical System
|
large 1800 /mm grating ruling, full closed optical system
|
Wavelength Range
|
190nm-900nm
|
Automatically peak find,a key opticaloptimization function
|
|
Wavelength Accuracy
|
≤0.15nm
|
Wavelength Repeatability
|
±0.1nm
|
Spectral Bandwidth
|
0.1nm,0.2nm,0.4nm,1.0nm,2.0nm
|
(5 steps with automatic changeover)
|
|
Baseline Stability
|
≤±0.002A/30 min (Static)
|
≤±0.005A/30min (Dynamic)
|
|
Absorbance Range
|
0-4A
|
Graphite Furnace Analytical System
|
|
Heating Mode
|
vertical heating
|
Temperature Control Method
|
vertical optical temperature monitoring graphite tube wall temperature
|
Temperature Range
|
room temperature to 3000℃
|
The Program
|
automatic temperature control up to 20 order
|
Temperature Control
|
the furnace enriched up to 20 times
|
Characteristics Volume
|
0.5 × 10-12g (Cd)
|
Detection Limit
|
0.4 × 10-12g (Cd)
|
Precision
|
RSD≤3%
|
The Cooling Water
|
can choose cooling water circulation system
|
Safety
|
the graphite tube damage, water flow
|
air pressure and other alarmtemperature overheating protection
|
|
Autosampler Graphite Furnace
|
|
Sample Tray
|
70 sample cups, 6 reagent cup
|
Sample Volume
|
1-100μl
|
The Smallest Lincrement
|
0.1 μl
|
The Volume of Sample
|
better than 1%(at the time of 10mL-100mL)
|
Repeatability Volume
|
|
Repeated Sampling Frequency
|
up to 99 Times
|
Cleaning and Waste
|
each 500mL
|
Container Volume
|