Product Details

Place of Origin: CHINA

Brand Name: Macylab

Certification: ALL OF MADE IN CHINA

Model Number: ICP6810

Payment & Shipping Terms

Minimum Order Quantity: 1

Price: TALK ABOUT IT

Packaging Details: PE film then pur into wooden carton

Delivery Time: Within 5 days

Payment Terms: L/C, T/T, Western Union, MoneyGram

Supply Ability: 120SET/DAY

Get Best Price
Highlight:

full spectrum laboratory spectrophotometer

,

800w laboratory spectrophotometer

,

27.12mhz spectrophotometry lab

Working Frequency:
27.12MHz
Frequency Stability:
﹤0.05%
Output Power:
800W ~1600W
Output Power Stability:
≤0.05%
OMatching Way:
Automatic Matching
Light Path:
Full Reflection Imaging Light Path, Quartz Prism Two-dimensional Dispersion System
Working Frequency:
27.12MHz
Frequency Stability:
﹤0.05%
Output Power:
800W ~1600W
Output Power Stability:
≤0.05%
OMatching Way:
Automatic Matching
Light Path:
Full Reflection Imaging Light Path, Quartz Prism Two-dimensional Dispersion System
Full Spectrum 800w Laboratory Spectrophotometer 27.12mhz Working Frequency

ICP6810 in the nonferrous gold industry

The ICP6810 profile is introduced

The ICP6810 full spectrum direct-read inductance-coupled plasma emission spectrometer, with excellent resolution, test accuracy and precision, is widely used in the rare earth industry, chemical industry, andOre analysis, metal smelting, geological research, drug safety, experimental research, environmental testing, food safety and other industries.Especially for the determination of elements in the ICP6810 zinc oxide industry.

picture1.ICP6810

Full Spectrum 800w Laboratory Spectrophotometer 27.12mhz Working Frequency 0

 

Table 1. Main technical parameters of ICP6810

ICP6810 main technical parameters

High frequency ionizer
Working frequency 27.12MHz
Frequency stability ﹤0.05%
Output power 800W ~1600W
Output power stability ≤0.05%
OMatching way Automatic matching
Scan the light divider
light path Full reflection imaging light path, quartz prism two-dimensional dispersion system
focal distance 400mm
Graster specifications Middle step grating, 52.67, l p / mm, 64 shining angle
Resolution ratio <0.0068nm@200nm
Complete machine technical indicators
Scan the wavelength range At 165-900nm, full wavelength coverage, and measurable Al 167.120nm
Repetitiveness RSD≤1.5%
Stability RSD≤2.0%
 

ICP6810 element detection limit (g / L)

element La Ce Pr Nd Sm Eu Gd Tb
wavelength (nm) 408.672 413.765 414.311 401.225 360.946 381.967 342.247 350.917
detection limit <3.0 <5.0 <5.0 <5.0 <10.0 <1.0 <10.0 <3.0
 

 

element Dy Ho Er Tm Yb Lu Y Sc
wavelength (nm) 353.170 345.600 337.271 313.126 369.419 261.541 371.030 335.373
detection limit <3.0 <3.0 <3.0 <3.0 <1.0 <3.0 <1.0 <1.0
 

 

element Ta Nb Mn Mg B Zn Co Si
wavelength (nm) 226.230 313.340 257.610 279.553 249.773 213.856 228.616 251.611
detection limit <5.0 <5.0 <3.0 <1.0 <10.0 <3.0 <3.0 <10.0
 

 

element Ni Cd Fe Ca Mo V Be Ti
wavelength (nm) 232.003 226.502 239.562 393.366 281.615 310.230 313.041 334.941
detection limit <5.0 <3.0 <3.0 <1.0 <5.0 <5.0 <1.0 <3.0
 

 

element Cu Cr Al Zr Ag Sr Au Pt
wavelength (nm) 324.754 267.716 396.152 343.823 328.068 407.771 242.795 265.945
detection limit <3.0 <5.0 <5.0 <5.0 <3.0 <1.0 <5.0 <5.0
 

 

element Pd Ir Rh Ru Ba Li Na K
wavelength (nm) 340.458 224.268 343.489 240.272 455.403 670.784 588.995 766.490
detection limit <5.0 <10.0 <10.0 <5.0 <1.0 ≤3 ≤20 ≤60
 

 

element As Sb Bi Hg Pb Ga Os W
wavelength (nm) 228.812 206.833 223.061 253.652 220.353 294.364 225.585 207.911
detection limit ≤15 ≤15 ≤10 ≤15 ≤15 ≤10 ≤1 ≤10
 

 

element Sn Te Ta Th Tl Re Ge Se
wavelength (nm) 242.949 214.281 226.230 283.730 276.787 227.525 209.426 203.985
detection limit ≤20 ≤10 ≤5.0 ≤10 ≤30 ≤5 ≤15 ≤30
 

●Evaluation of alloy measurable elements in non-ferrous precious metals

For precious metal samples and customer test requirements, the details are shown in the Table:

2. Precious metal sample test solution

sample measureelement Analysis instrument Sample handling overview (for reference only) remarks
Non-ferrous precious metal alloy Gold, silver, palladium, platinum, and so on ICP6810 Take 0.1-0.3g sample in a 100ml beaker, add 5ml hydrochloric acid, dissolve the sample on the heating plate to clarification, remove cold to room temperature, transferred to 50ml volumetric flask diluted with water to scale for testing. Sample blank experiment was also performed simultaneously duringthesampleprocessing process.
 

 

According to the configured standard solution concentration, directly on the computer test, the instrument can automatically give the final test results, and can be directly printed in the form of a report.

Table 3.ICP6810 and related instrument configuration

Instrument host and necessary accessories
order number definition Specifications / models manufacturer quantity remarks quantity remarks
1 Full-spectrum straight-read inductively coupled plasma emission spectrometer ICP6810 Shanghai Beauty Instrument Co., Ltd 1  
2 Automatic temperature control and circulating cooling water device     1  
3 stabilized voltage supply     1  
Instrument matching accessories
order number definition Specifications / models manufacturer quantity remarks quantity remarks
1 host     1  
2 graphoscope     1  
3 marking punch     1  
Sample processing equipment and consumables
order number definition Specifications / models manufacturer quantity remarks quantity remarks
1 Electronictemperature-controlled heating board EG-35B   1  
2 One in ten thousand is an electronic balance BS224S   1  
3 Laboratory-grade ultra-pure water machine EPED-40T   1  
4 Disposable rubber Gloves M   /  
5 Activated carbon mask     /  
6 3mlpasteurpipette 3ml   /  
7 100mlglass beaker 100ml Sichuan Shu Glass scientific Instruments /  
8 100mlGlass capacity bottle 100ml Sichuan Shu Glass scientific Instruments /  
9 5mltransfer liquid gun 0.5ml-5ml Rand, Germany 1  
10 1mltransfer liquid gun 100ul-1000ul Rand, Germany 1  
Reagent
order number definition Specifications / models manufacturer quantity remarks quantity remarks
1 hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd /  
2 hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd /  
3 perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd /  
4 Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis /  
             
 

 

If you have any other questions, please call the analysis instrument