Product Details

Place of Origin: China

Brand Name: Macylab

Certification: CE,FCC,FDA,ROHS,9001

Model Number: IPC6810

Payment & Shipping Terms

Minimum Order Quantity: 1pcs

Price: USD2900--USD3800/SET

Packaging Details: Waterproof paper then Carton

Delivery Time: at once

Payment Terms: Western Union, MoneyGram, L/C, T/T,

Supply Ability: 50000Set / month

Get Best Price
Highlight:

full spectrum spectrophotometry lab

,

direct reading spectrophotometry lab

,

laboratory spectrophotometer direct reading

Name:
ICP-6810 Induced Coupled Plasma Optical Emission Spectroscopy FCC
Keyword:
Induced Coupled Plasma Optical Emission Spectroscopy
Ce:
Ok
Model:
IPC6800
Output Power:
800 -1500W
Total Argon Consumption:
≤14L/min
Output Power:
800-1500W
Wavlength Range:
165nm-900nm
Stability:
RSD<1.5%(within 2 Hours)
Color:
Blank And Red
Name:
ICP-6810 Induced Coupled Plasma Optical Emission Spectroscopy FCC
Keyword:
Induced Coupled Plasma Optical Emission Spectroscopy
Ce:
Ok
Model:
IPC6800
Output Power:
800 -1500W
Total Argon Consumption:
≤14L/min
Output Power:
800-1500W
Wavlength Range:
165nm-900nm
Stability:
RSD<1.5%(within 2 Hours)
Color:
Blank And Red
Icp-6810 Spectrophotometry Lab Full Spectrum Direct Reading Inductively Coupled Plasma Emission

Application Field

 

ICP-6810 is a full-spectrum direct-reading inductively coupled plasma emission spectrometer for the determination of trace and trace elements in different substances (dissolved in nitric acid, hydrochloric acid, hydrofluoric acid, etc.). It is widely used in environmental protection, petroleum products, rare earth, semiconductor, geology, metallurgy, chemical industry, clinical medicine, food, biological samples, criminal science, agricultural research and other fields.
Performance characteristics
Performance stability
The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.


Injection automation
Adopting four-channel automatic design, the rotational speed can be set up according to the test demand to adjust the flow rate, carrier gas, plasma gas, auxiliary gas are all controlled by advanced mass flow controller, at the same time can be equipped with imported high salt nebulizer, imported hydrofluoric nebulizer and so on to meet the customer's various test needs.


Precision analysis
The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.


Quick test
In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.
Technical parameters of the instrument
Output power: 800 -1500W

Total argon consumption:≤14L/min

Wavelength range:160nm - 1000 nm

Resolution: < 0.0065nm@200nm
Instrument technical index
Method of observation: vertical observation
Liquid content:0.01ppm~thousands of ppm.
Solid content:0.001%~70%
Repeatability: RSD < 1%
Stability: RSD <1.5%(within 2 hours)
Element detection limit (μg/L): most elements 1ppb~10ppb

Application area

Silicon industry, metallurgical industry, water quality analysis, geology, ore analysis, petrochemical, medical, sanitary, agricultural environmental protection, commodity, food quality inspection.

Icp-6810 Spectrophotometry Lab Full Spectrum Direct Reading Inductively Coupled Plasma Emission 0

Icp-6810 Spectrophotometry Lab Full Spectrum Direct Reading Inductively Coupled Plasma Emission 1

ICP-6800S Inductively Coupled Plasma Optical Emission Spectrometer(Petrochemical)

Application Field

Petrochemical Inductively Coupled Plasma Optical Emission Spectrometer(ICP6800S) is a professional instrument for the petrochemical industry launched by Macylab Instruments. It can be used to determine more than 30 elements in crude oil, mainly for Fe.Na.Mg.Ni. V.Ca. Pb.Mo.Mn.Cr.Ca.Ba.As; also can be used to measure iron, manganese, lead, silicon in gasoline ,and the Wear elements of additive in lubricating oil, it also can be applied for multielement determination in base oils; for the determination of sodium in formaldehyde and the determination of oil field tracer.

 

 

Application Environment

CONTENT RANGE

Shipping/Storage Ambient Temperature 15℃-25℃

Shipping/Storage Relative Humidity ≤70%

Atmospheric pressure 86-106 kPa

Power Supply 220±10V 50-60MHz

Working Humidity ≤70%

Working Temperature 15℃-30℃

 

Technical Parameter

RFPower technical parameter:

Circuit type: solid-state RF power supply, with function of automatch

Frequency: 27.12MHz±0.05%

Frequency Stability: <0.1%

Power Output: 800W—1500W

Power Output Stability: <0.3%

Escaped RF radiation: 30cm away from the instrument, electric field: E﹤2V/m

 

Sampling System Technical Parameter:

Output working coil inner diameter :25mm

Torque tube: Three concentric, external diameter 20mm

Coaxial nebulizer:Outer diameter 6mm

Double barrel atomizing chamber: Outer diameter 34mm

 

Gas Flow Controls

1. Plasma Argon Flowmeter:(100-1000)L/h (1.6-16L/min)

2. Auxiliary Argon Flowmeter:(10-100)L/h (0.16-1.66L/min)

3. Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min)

4.Oxygen Flowmeter:(0-100)ml/min (30-50ml/min)

5.Pressure Maintaining Valve(0-0.4MPa)

6.Cooling Water:Temperature: 20-25℃, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa

 

Spectrometer

Optics:Czerny-Turner type

Focal length: 1000 mm

Grating: Ion Beam Etching Holographic Grating, 4320L/mm

Reciprocal linear dispersion: 0.26nm/mm

Resolution:≤ 0.005nm (4320 line grating)

Wavelength range: 4320 line grating:(180nm~435) nm

Minimum pace of stepping motor: ≤0.0006 nm

Exit Slit:10μm;Entrance Slit:8μm

 

Photoelectric Converter Performance

Photomultiplier tube specification: R293

Negative HV on PMT: 0-1000V;Stability: <0.05%

 

Refrigeration System

Refrigerating Swirling Fog Chamber:The use of imported silica gel collection technology can make the temperature drop to 20 degrees below zero

 

Overall Performance

Wavelength range of scanning: 185nm~435nm(4320L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Detection Limits (µg/L):

Direct injection sampling and measure iron(Fe), manganese(Mn), lead(Pb) and silicon(Si) in gasoline.Analysis results:

Element Fe Mn Pb Si
Determination value/(mg/L) 3.6 17.5 1.8 2.4
RSD/% 0.56 0.23 1.38 0.92

 

Standard Additionand Recovery Rate:

Number

Standard Addition

(mg/L)

Fe Mn Pb Si
    Determination value(mg/L)

Recovery

/%

Determination value(mg/L)

Recovery

/%

Determination value(mg/L)

Recovery

/%

Determination value(mg/L)

Recovery

/%

1 0.45 0.436 96.9 0.468 104.0 0.432 96.0 0.465 103.3
2 0.9 0.887 98.6 0.913 101.4 0.868 96.4 0.919 102.1
 
 
Icp-6810 Spectrophotometry Lab Full Spectrum Direct Reading Inductively Coupled Plasma Emission 2

ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard)

Application Field

Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.

At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.

 

Application Environment

CONTENT RANGE

Shipping/Storage Ambient Temperature 15℃-25℃

Shipping/Storage Relative Humidity ≤70%

Atmospheric pressure 86-106 kPa

Power Supply 220±10V 50-60MHz

Working Humidity ≤70%

Working Temperature 15℃-30℃

 

RFPower technical parameter:

Circuit type: solid-state RF power supply, with function of automatch

Frequency: 27.12MHz±0.05%

Frequency Stability: <0.1%

Power Output: 800W—1200W

Power Output Stability: <0.3%

Escaped RF radiation: 30cm away from the instrument, electric field: E﹤2V/m

 

Sampling System Technical Parameter:

Output working coil inner diameter :25mm

Torque tube: Three concentric, external diameter 20mm

Coaxial nebulizer:Outer diameter 6mm

Double barrel atomizing chamber: Outer diameter 34mm

 

Gas Flow Controls

1. Plasma Argon Flowmeter:(100-1000)L/h (1.6-16L/min)

2. Auxiliary Argon Flowmeter:(10-100)L/h (0.16-1.66L/min)

3. Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min)

4.Pressure Maintaining Valve(0-0.4MPa)

5.Cooling Water:Temperature: 20-25℃, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa

 

Spectrometer

Optics:Czerny-Turner type

Focal length: 1000 mm

Grating: Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm

Reciprocal linear dispersion: 0.26nm/mm

Resolution:≤ 0.007nm (3600 line grating);≤0.015nm (2400line grating)

Wavelength range: 3600 line grating:(190nm~500) nm;2400 line grating: (190nm~800) nm

Minimum pace of stepping motor: ≤0.0006 nm

Exit Slit:12μm;Entrance Slit:10μm

 

Photoelectric Converter Performance

Photomultiplier tube specification: R293/R928

Negative HV on PMT: 0-1000V;Stability: <0.05%

 

Overall Performance

Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Detection Limits (µg/L):

Detection Limits (µg/L):

Element WL(nm) Limit   Element WL(nm) Limit

 

La

 

408.672

 

<3.0

 

 

Cr

267.716 <5.0
Ce 413.765

 

<5.0

 

 

Al

 

396.152

<5.0
Pr

 

414.311

 

<5.0

 

 

Zr

 

343.823

 

<5.0

 

Nd

401.225 <5.0  

 

Ag

328.068 <3.0
Sm 360.946

 

<10.0

 

 

Sr

 

407.771

<1.0

 

Eu

 

381.967

 

<1.0

  Au

 

242.795

<5.0

 

Gd

 

342.247

<10.0   Pt 265.945

 

<5.0

 

Tb

 

350.917

 

<3.0

 

 

Pd

 

340.458

<5.0
Dy 353.170 <3.0  

 

Ir

 

224.268

<10.0
Ho

 

345.600

 

<3.0

 

 

Rh

343.489

 

<10.0

 

Er

 

337.271

 

<3.0

 

 

Ru

 

240.272

 

<5.0

Tm

 

313.126

 

<3.0

  Ba

 

455.403

 

<1.0

Yb

 

369.419

 

<1.0

  As

 

228.812

≤15

 

Lu

261.541 <3.0  

 

Sb

206.833 ≤15
Y 371.030 <1.0  

 

Bi

223.061 ≤10
Sc 335.373

 

<1.0

 

 

Hg

253.652

 

≤15

Ta

 

226.230

<5.0  

 

Pb

220.353 ≤15

 

Nb

313.340

 

<5.0

  Ga 294.364 ≤10
Mn

 

257.610

 

<3.0

 

 

Se

203.985 ≤10

 

Mg

 

279.553

 

<1.0

  Sn

 

242.949

≤20

 

B

 

249.773

 

<10.0

 

 

Te

214.281

 

≤10

Zn 213.856 <3.0  

 

Ta

226.230 ≤5.0

 

Co

228.616

 

<3.0

  Th 283.730

 

≤10

Si

 

251.611

<10.0  

 

Tl

276.787 ≤30

 

Ni

 

232.003

<5.0   Re 227.525 ≤5视频中心

 

Cd

 

226.502

<3.0   Ge

 

209.426

≤15

 

Fe

239.562

 

<3.0

 

 

Os

225.585 ≤1

 

Ca

 

393.366

 

<1.0

 

 

W

207.911 ≤10

 

Mo

 

281.615

<5.0   Cu

 

324.754

 

<3.0

V 310.230 <5.0  

 

Li

670.784

 

≤3

 

Be

313.041 <1.0   Na 588.995 ≤20
Ti

 

334.941

<3.0  

 

K

 

766.490

≤60

 

 

 

Icp-6810 Spectrophotometry Lab Full Spectrum Direct Reading Inductively Coupled Plasma Emission 3

 

 

 

 

Icp-6810 Spectrophotometry Lab Full Spectrum Direct Reading Inductively Coupled Plasma Emission 4

 

Icp-6810 Spectrophotometry Lab Full Spectrum Direct Reading Inductively Coupled Plasma Emission 5