Home ProductsDual Beam Spectrophotometer

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel

  • 195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel
  • 195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel
195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel
Product Details:
Place of Origin: China
Brand Name: Macylab
Certification: CE ISO ROHS FCC FAD
Model Number: ICP-6800
Payment & Shipping Terms:
Minimum Order Quantity: 1pcs
Price: USD33900/Set
Packaging Details: Wood Box
Delivery Time: 20-300days
Payment Terms: Western Union, MoneyGram, T/T, L/C
Supply Ability: 5000Set / year
Contact Now
Detailed Product Description
Product Name: Inductively Coupled Plasma Optical Emission Spectrometer Key Words: Single Channel
Optical Structure: Czerny-Turner Frequency: 27.12MHz±0.05%
Repeatibility: RSD<=1.5% Stability: RSD <=2%
Output Power: 800W-1200W Dimensions: 125x69.3x64.5cm
Scanning Wavelength Range: 195nm-500nm(3600L/mm Grating), 195mm-500nm(2400L/mm Grating) Photomultiplier Specification: R293 Or R298
High Light:

195nm czerny turner spectrometer

,

single channel czerny turner spectrometer

 

                               Inductively Coupled Plasma Optical Emission Spectrometer ICP-6800                               

 

   

   

 

 

Main features

Performance stability:The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.

Injection automation:Adopting four-channel automatic design, the rotational speed can be set up according to the test demand to adjust the flow rate, carrier gas, plasma gas, auxiliary gas are all controlled by advanced mass flow controller, at the same time can be equipped with imported high salt nebulizer, imported hydrofluoric nebulizer and so on to meet the customer's various test needs.

Precision analysis:The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.

Quick test:In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis


 

 

Technical parameters

 

RFPower technical parameter

 

Circuit type :solid-state RF Power supply, with function of automatch

 

Frequercy :27.12MHz±0.05%

 

Frequency Stablity :<0.1%

 

Power Output :800W-1500W

 

Power Output Stability :<0.3%

 

Escaped RF radiation :30cm away from the instrument, electric fiekd: E<2Vtm

 

Sampling System Technical Parameter

 

Output working coil imer diameter :25mm

 

Torpue tube:Three concentric, extemal diameter 20mm

 

Coaxial nebulizer :Outer dameter 6mm

 

Double barrel atomizing chamber:Outer diameter 34mm

 

 

Gas Flow Controls

 

Plasma Argon Flowmeter :(100-1000)L/h(1.6-16L/min)

 

Auxiliary Argon Fiowmeter :(100-1000)L/h(0.16-1.6L/min)

 

Auxiliary Carrier Argon Flowmeter :(100-1000)L/h(0.16-1.6L/min)

 

Pressune Maintaining Value :(0-0.4MPa)

 

Cooling Water:Temperature :20-25ºC,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa

          


 

                                                                            Certificate                                                                                      195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel 0

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel 1

 

Spectrometer

 

Optics Czerny-Turner type

 

Focal length 1000 mm

 

Grating Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm

 

Reciprocal linear dispersion 0.26nm/mm

 

Resolution ≤0.007nm(3600 line grating); ≤0.015nm(2400 line grating)

 

Wavelength range 3600 line grating:(190nm~500) nm; 2400 line grating:(190nm~800) nm

 

Minimum pace of stepping motor ≤0.0006 nm

 

Exit Slit 12μm

 

Entrance Slit 10μm

 

Photoelectric Converter Performance

 

Photomultiplier tube specification :R293/R928

 

Negative HV on PMT 0-1000V

 

Stability <0.05%

 

Overall Performance Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

 

Repeatability: RSD(Relative Standard Deviation)≤1.5%

 

Stability: RSD(Relative Standard Deviation) ≤2%

 

Exhibition:

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel 2

Our Company:

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel 3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Factory:

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel 4

195nm-500nm Czerny Turner Spectrometer 3600l/Mm Grating Single Channel 5

Contact Details
Macylab Instruments Inc.

Contact Person: MacylabMaria

Tel: +8615031364615

Send your inquiry directly to us (0 / 3000)

Other Products