Send Message
products
PRODUCTS
Home > Products > Single Beam Spectrophotometer > 0.2nm Single Beam Instrument Import Deuterium Lamp And Import Tungsten Lamp

0.2nm Single Beam Instrument Import Deuterium Lamp And Import Tungsten Lamp

Product Details

Place of Origin: China

Brand Name: Macylab

Certification: CE ISO

Model Number: UV-1100

Payment & Shipping Terms

Minimum Order Quantity: 1set

Price: usd 700/set

Packaging Details: carton

Payment Terms: D/A, D/P, L/C, T/T, Western Union

Supply Ability: 5000set per year

Get Best Price
Highlight:

deuterium lamp single beam instrument

,

0.2nm single beam instrument

,

tungsten lamp single beam spectrometer

NAME:
Macylab Single Beam Uv Visible Spectrophotometer Import Deuteriumlamp And Import Tungsten Lamp
KEY WORDS:
Macylab Single Beam Uv Visible Spectrophotometer Import Deuteriumlamp And Import Tungsten Lamp
WAVELENGTH RANGE:
200-1000nm
BAND WIDTH:
4nm
WAVELENGTH ACCURACY:
±2.0nm
WAVELENGTH REPEATABILITY:
0.2nm
DETECTOR:
Imoport Silicon Photodiode
Light Source:
Import Deuteriumlamp And Import Tungsten Lamp
Photometric Accuracy:
±0.5%T
PHOTOMETER REPEATABILITY:
0.2%T
STRAY LIGHT:
≤0.05%
PHOTOMETER MODE:
T,A,C,E
WAVELENGTH SETTING:
Automatic
Weight:
11kg
Dimensions:
460*330*210mm
NAME:
Macylab Single Beam Uv Visible Spectrophotometer Import Deuteriumlamp And Import Tungsten Lamp
KEY WORDS:
Macylab Single Beam Uv Visible Spectrophotometer Import Deuteriumlamp And Import Tungsten Lamp
WAVELENGTH RANGE:
200-1000nm
BAND WIDTH:
4nm
WAVELENGTH ACCURACY:
±2.0nm
WAVELENGTH REPEATABILITY:
0.2nm
DETECTOR:
Imoport Silicon Photodiode
Light Source:
Import Deuteriumlamp And Import Tungsten Lamp
Photometric Accuracy:
±0.5%T
PHOTOMETER REPEATABILITY:
0.2%T
STRAY LIGHT:
≤0.05%
PHOTOMETER MODE:
T,A,C,E
WAVELENGTH SETTING:
Automatic
Weight:
11kg
Dimensions:
460*330*210mm
0.2nm Single Beam Instrument Import Deuterium Lamp And Import Tungsten Lamp


 

 

Spectrometer

Wavelength Range 200~1000nm
Band Width 4nm
Wavelength Accuracy ±2.0 nm
Wavelength Repeatability 0.2nm
Photometric Accuracy ±0.5% τ
Photometric Repeatability 0.2% τ
Stray Light ≤0.05% τ (220nm NaI,340nm NaNO2)
Stability 0.001A/30min@500nm
Photometric Mode T,A,C,E
Wavelength Setting Automatic
Photometric Display Range -0.3~3A
Display Mode LCD Screen (128*64 Dots).
Detector Import Silicon Photodiode
Light Source Import Lamp & Tungsten Halogen Lamp
Power Requirement AC 220V/50Hz 110V/60Hz
Power 120W
Dimensions(W*D*H) 460×330×210mm
Weight 11KG

 

 

Competitive Advantage:

1.Single-chip microcomputer control, LCD Screen (128*64 Dots)  
2.Large LCD display can display multiple sets of data  
3.Huge memory space to store multiple sets of data and curves  
4.Auto zero,100% adjustment function  
5.Wavelength automatic adjustment  
6.Wrap lights, automatic filter change, large sample pool (0.5mm ~ 100mm)  
7.Standard samples having a maximum ten-point standard curve measurement functions built  
8.Direct input by K, B factor for quantitative measurement standard curve  
9.Can be directly input and the corresponding standard concentration values ​​establish a standard curve for quantitative measurement
10.Adjustable electric saving standard curve parameter measuring set, can save a plurality of standard curve
11.Can be edited at any time of the standard curve, user-friendly  
12.General Parallel printer interface with or slightly beat interfaces can print the title bar, the measurement data, curve parameters, the standard curve and the curve sample points
13.With USB interface  
14.Can achieve more accurate and flexible measurement requirements (optional) via PC control

 

 

Macylab Instruments Inc. operates spectroscopic instruments, such as spectrophotometers, UV-visible spectrophotometers, atomic absorption spectrometers, ultra-micro spectrophotometers, atomic fluorescence spectrophotometers, ICP inductively coupled plasma emission spectrometers. Currently, our products have been Widely used in organic chemistry, inorganic chemistry, biochemistry, medicine, environmental protection, metallurgy, petroleum, agriculture and other fields. At the same time, the company has accumulated a wealth of experience in product mechanical structure, optical design, electrical applications and software development, combined with the latest practical needs of the market, will soon launch a number of new analytical instruments.
Macy's headquarter and production base is located in Shanghai, the marketing center in Beijing, and three R & D bases in Jiangsu, Shanghai, and Shandong. To take full advantage of the country's intellectual resources, MACY and the domestic and foreign research unit also conducted deep scientific research cooperation, will continue to put the research achievements into productivity .To better serve our customers, Macy has 12 domestic offices, tailored to meet the needs of your application solutions to improve the value of the products. At the same time continue to serve domestic users, Macy also with distribution in over 20 countries to establish a deep strategic partnership cooperation.
Along with Macy accelerate the pace and rank among the global brand instruments, Macy increasing demands of our own, and we also hope to get the care and support of the community, Let us work and outlook together.Technology, will change because you and us.Macylab UV-V Spectrophotometer Basic Version Instrument Manufacturers