Product Details

Place of Origin: China

Brand Name: Macybab

Certification: RoHS, ISO9001, CE

Model Number: V-1100

Payment & Shipping Terms

Minimum Order Quantity: 1 piece

Price: USD 262-308 $

Packaging Details: 60*45*32cm

Delivery Time: Received payment,within 10 days of delivery

Payment Terms: L/C, , D/A, D/P, T/T

Supply Ability: 1 PC PER WEEK

Get Best Price
Highlight:

macylab visible spectrophotometer

,

tungsten lamp visible spectrophotometer

,

tungsten lamp uv vis spectrophotometer

Product Name:
Visible Spectrophotometer
Keyword:
Laboratory Spectrophotometer
WavLength Range:
325-1000nm
Wavelength Regulation:
Manual
Color:
Black And Red
Display:
LED
Light Source:
Imported Tungsten Lamp
Detector:
Imported Silicon Photodiode
Product Name:
Visible Spectrophotometer
Keyword:
Laboratory Spectrophotometer
WavLength Range:
325-1000nm
Wavelength Regulation:
Manual
Color:
Black And Red
Display:
LED
Light Source:
Imported Tungsten Lamp
Detector:
Imported Silicon Photodiode
Macylab Of Manual Visible Spectrophotometer Imported Tungsten Lamp

 

Macylab Visible Spectrophotometer Black And Red Imported Tungsten Lamp

 

visible spectrophotometer Product Description

 

1 .Single chip microcomputer control, digital display
2. Automatic 0 and 100% adjustment functions
3. Standard curve can be established by directly inputting F factor for concentration direct reading
4. The standard sample and corresponding concentration value can be directly input for concentration measurement
5. Equipped with general parallel printing interface, measurement data can be printed
6. Configuring a USB Port
7. More accurate and flexible measurement requirements can be realized through PC control (optional)

 

visible spectrophotometer Product Paramete

 

Mode V-1100
Wavelength Range 325~1000nm
Optical circuit structure autocollimation
Band Width 4nm
Wavelength Accuracy ±2.0nm
Wavelength Repeatability 1nm
Photometric Accuracy ±0.5% τ
Photometric Repeatability 0.2% τ
Stray Light ≤0.05% τ (340nm NaNO2)
Stability 0.001A/h@500nm
Photometric Mode T,A,C,E
Wavelength Setting Manual
Photometric Display Range -0.3~3A
Display Mode 4 LED
Detector Import Silicon Photodiode
Light Source Import Tungsten Halogen Lamp
Power Requirement AC 220V/50Hz 110V/60Hz
Power 120W
Dimensions(W*D*H) 360×280×190mm
Weight 9Kg

 

visible spectrophotometer Company Profile

 

Macy Lab attaches great importance to the introduction and training of talents, so that it has established a strong training team, to provide all-round training for on-the-job employees, to help employees to make career planning, in order to the common development of the company and employees. At the same time, Macy Lab inspires the staffs with the professional ethics of "family, dedication and learning". Each of Macy employee perfectly presents every instrument and serves every customer with full enthusiasm and professional skills.

 

 

 

Our visible spectrophotometer Advantages

 

Shanghai Macylab Instruments Inc. (Shorter form Macy Lab), Is a high-tech enterprise with independent intellectual property rights, Macy' s entrepreneurial concept is "Tech -- changes for you", and take this as the purpose of the enterprise, continuous exploration, bold innovation. Macy Lab mainly specializes in spectral instruments: Visible spectrophotometer, UV-visible spectrophotometer, atomic absorption spectrometer, atomic fluorescence photometer, ICP-AES,ICP-MS, Life sciences instruments: Ultra-trace spectrophotometer, fully automatic nucleic acid extraction instrument,At present, our products have been widely used in organic chemistry, inorganic chemistry, chemistry, biological chemistry, medicine, environmental protection, metallurgy, petroleum, agriculture and other fields. At the same time, with the rich experience accumulated in product mechanical structure, optical design, electrical application and software development, combined with the latest actual needs of the market, we will launch a batch of new analytical instruments in the near future.

 

 

visible spectrophotometer Exhibition

 

We have participated in exhibitions all over the world, such as India, Dubai, Russia, Singapore and so on. Every time, our booth is filled with consulting customers. Through experiencing our products, customers affirm the quality of our products, and our products are unanimously recognized at home and abroad

 

Macylab Of Manual Visible Spectrophotometer  Imported Tungsten Lamp 0

FAQ

 

Q1: Why choose Macy Lab visible spectrophotometer ?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a visible spectrophotometer factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: visible spectrophotometer OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the visible spectrophotometer price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your visible spectrophotometer Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the visible spectrophotometer after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the visible spectrophotometer M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: visible spectrophotometer Sample order is OK?
A8: visible spectrophotometer Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can visible spectrophotometer be used?
Q11: visible spectrophotometer can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the visible spectrophotometer delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a visible spectrophotometer sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.