Product Details

Place of Origin: China

Brand Name: Macylab

Certification: ROSH, FCC, CE, ISO9001

Model Number: UL-5000F

Payment & Shipping Terms

Minimum Order Quantity: 1pc

Price: $8710

Packaging Details: Cartons And Wooden Cases

Delivery Time: 5-8 work days

Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability: 1000pc

Get Best Price
Highlight:

nucleic acid ultraviolet visible spectrophotometer

,

protein detection ultraviolet visible spectrophotometer

,

Macylab uv vis spectrophotometer

Product Name:
Macylab Micro Volume Ultraviolet Visible Spectropeter Nucleic Acid And Protein Detection
Keyword:
Ultraviolet Visible Spectrophotometer
Minimum Sample Size:
0.5-2ul
Print:
Built-in Thermal Printer
Liquid Crystal Screen:
7 "touch Operation Works
Output Data:
USB
Optical Path:
0.05mm,0.2mm,1.0mm
Detector:
COMS
Product Name:
Macylab Micro Volume Ultraviolet Visible Spectropeter Nucleic Acid And Protein Detection
Keyword:
Ultraviolet Visible Spectrophotometer
Minimum Sample Size:
0.5-2ul
Print:
Built-in Thermal Printer
Liquid Crystal Screen:
7 "touch Operation Works
Output Data:
USB
Optical Path:
0.05mm,0.2mm,1.0mm
Detector:
COMS
UL-5000F Ultraviolet Visible Spectrophotometer Nucleic Acid And Protein Detection

Macylab Micro Volume Ultraviolet Visible Spectropeter Nucleic Acid And Protein Detection

 

Product description

 

Micro volume spectrophotomeler is an important analysis instrumert wildly ,in research of physics, chemistry, biology, medicine, materi-al, eriviroment and rocdern production mansgement of chemistry, medicine, enviromerit test, metallurgy. Spectrophotometer is the instrument for quantitative and quantitabve analysis by spectophotormetry. It is usually used in quatitative research of nucleicacid,proteins and bacterial conoentration.

 

Technical Parameters

 

 

Range Wavelength 190~850nm
Optical path 0.05mm,0.2mm,1.0mm
Light Xenon lamp
Wavelength resolution 2nm
Absorption accuracy 0.003Abs(0.2mm Optical path)
Absorbance range 0.04~300A(Equivalent 10mm optical path)
OD600 Absorbance Range 0~6.000Abs
Fluorescence detection linearity R2>0.996
Nucleic acid detection range 2-15000ng/ul(dsDNA)
Display Seven inch touch screen
Power 25W

 

 

 

Our company

 

Macy Lab attaches great importance to the introduction and training of talents, so that it has established a strong training team, to provide all-round training for on-the-job employees, to help employees to make career planning, in order to the common development of the company and employees. At the same time, Macy Lab inspires the staffs with the professional ethics of "family, dedication and learning". Each of Macy employee perfectly presents every instrument and serves every customer with full enthusiasm and professional skills.

 

UL-5000F Ultraviolet Visible Spectrophotometer Nucleic Acid And Protein Detection 0

 

 

Exhibition

 

The International Exhibition of Analytical Instruments was held in Munich, Federal Germany. The exhibition was attended by 1,400 scientific and professional workers from 40 countries in the fields of chemistry, biochemistry, medical diagnostics, environmental protection, food chemistry and pharmaceutical chemistry. A total of 513 companies from 20 countries participated in the exhibition, and Macylab Instruments was welcomed by customers from all over the world at the exhibition

 

 

 

UL-5000F Ultraviolet Visible Spectrophotometer Nucleic Acid And Protein Detection 1

 

 

 

 

 

Software Functions

 

* English and Chinese interface switch to meet the customer's usage habits, the same experiment can be carried out at any time module switch; (Software screenshots should be provided for suppor

* multiple curves overlay display, can realize the three-dimensional map mode; (Software explanatory materials should be provided for support)

* intelligent induction measurement, advanced design and construction do not need to worry about the external mobile cantilever caused by uneven closure, or potential mechanical damage; No matter the viscosity of the sample is high or low, the Macylab ultramicroscopic spectrophotometer can ensure that the optical diameter is fixed, and obtain accurate and reliable experimental results.

 

FAQ

 

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.