Send Message
products
PRODUCTS
Home > Products > Inductively Coupled Plasma Optical Emission Spectrometer > Silicon Industry ICP-MS6880 Icp Mass Spectrometer For Laboratory

Silicon Industry ICP-MS6880 Icp Mass Spectrometer For Laboratory

Product Details

Place of Origin: China

Brand Name: Macylab

Certification: CE,FCC,FDA,ROHS,9001

Model Number: IPC6880-MS

Payment & Shipping Terms

Minimum Order Quantity: 1pcs

Price: negotiable

Packaging Details: Waterproof paper then Carton

Delivery Time: at once

Payment Terms: Western Union, MoneyGram, L/C, T/T,

Supply Ability: 50000Set / month

Get Best Price
Highlight:

silicon industry icp mass spectrometer

,

laboratory icp mass spectrometer

,

laboratory inductively coupled plasma mass spectrometer

Name:
Icp-6880 Induced Coupled Plasma Optical Emission Spectroscopy FCC
Keyword:
Induced Coupled Plasma Optical Emission Spectroscopy
Ce:
Ok
Model:
IPC6880
Output Power:
800 -1500W
Total Argon Consumption:
≤14L/min
Name:
Icp-6880 Induced Coupled Plasma Optical Emission Spectroscopy FCC
Keyword:
Induced Coupled Plasma Optical Emission Spectroscopy
Ce:
Ok
Model:
IPC6880
Output Power:
800 -1500W
Total Argon Consumption:
≤14L/min
Silicon Industry ICP-MS6880 Icp Mass Spectrometer For Laboratory

 

Silicon industry ICP-MS6880 Inductively Coupled Plasma Mass Spectrometer For Laboratory

 

ICP-6880 is a full-spectrum direct-reading inductively coupled plasma emission spectrometer for the determination of trace and trace elements in different substances (dissolved in nitric acid, hydrochloric acid, hydrofluoric acid, etc.). It is widely used in environmental protection, petroleum products, rare earth, semiconductor, geology, metallurgy, chemical industry, clinical medicine, food, biological samples, criminal science, agricultural research and other fields.


Quick test
In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.
Technical parameters of the instrument
Output power: 800 -1500W

Total argon consumption:≤14L/min

Wavelength range:160nm - 1000 nm

Resolution: < 0.0065nm@200nm
Instrument technical index
Method of observation: vertical observation
Liquid content:0.01ppm~thousands of ppm.
Solid content:0.001%~70%
Repeatability: RSD < 1%
Stability: RSD <1.5%(within 2 hours)
Element detection limit (μg/L): most elements 1ppb~10ppb

Application area

Silicon industry, metallurgical industry, water quality analysis, geology, ore analysis, petrochemical, medical, sanitary, agricultural environmental protection, commodity, food quality inspection.

 

Silicon Industry ICP-MS6880 Icp Mass Spectrometer For Laboratory 0

ICP-6880 Inductively Coupled Plasma Optical Emission Spectrometer(Petrochemical)

Application Field

Petrochemical Inductively Coupled Plasma Optical Emission Spectrometer(ICP6800S) is a professional instrument for the petrochemical industry launched by Macylab Instruments. It can be used to determine more than 30 elements in crude oil, mainly for Fe.Na.Mg.Ni. V.Ca. Pb.Mo.Mn.Cr.Ca.Ba.As; also can be used to measure iron, manganese, lead, silicon in gasoline ,and the Wear elements of additive in lubricating oil, it also can be applied for multielement determination in base oils; for the determination of sodium in formaldehyde and the determination of oil field tracer.

 

 

Gas Flow Controls

1. Plasma Argon Flowmeter:(100-1000)L/h (1.6-16L/min)

2. Auxiliary Argon Flowmeter:(10-100)L/h (0.16-1.66L/min)

3. Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min)

4.Oxygen Flowmeter:(0-100)ml/min (30-50ml/min)

5.Pressure Maintaining Valve(0-0.4MPa)

6.Cooling Water:Temperature: 20-25℃, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa

 

Direct injection sampling and measure iron(Fe), manganese(Mn), lead(Pb) and silicon(Si) in gasoline.Analysis results:

Element Fe Mn Pb Si
Determination value/(mg/L) 3.6 17.5 1.8 2.4
RSD/% 0.56 0.23 1.38 0.92

 

Standard Additionand Recovery Rate:

Number

Standard Addition

(mg/L)

Fe Mn Pb Si
    Determination value(mg/L)

Recovery

/%

Determination value(mg/L)

Recovery

/%

Determination value(mg/L)

Recovery

/%

Determination value(mg/L)

Recovery

/%

1 0.45 0.436 96.9 0.468 104.0 0.432 96.0 0.465 103.3
2 0.9 0.887 98.6 0.913 101.4 0.868 96.4 0.919 102.1
 
 
 

ICP-6800 Inductively Coupled Plasma Optical Emission Spectrometer(standard)

Application Field

Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.

At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.

 

Application Environment

CONTENT RANGE

Shipping/Storage Ambient Temperature 15℃-25℃

Shipping/Storage Relative Humidity ≤70%

Atmospheric pressure 86-106 kPa

Power Supply 220±10V 50-60MHz

Working Humidity ≤70%

Working Temperature 15℃-30℃

 

Overall Performance

Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Detection Limits (µg/L):

Detection Limits (µg/L):

Element WL(nm) Limit   Element WL(nm) Limit

 

La

 

408.672

 

<3.0

 

 

Cr

267.716 <5.0
Ce 413.765

 

<5.0

 

 

Al

 

396.152

<5.0
Pr

 

414.311

 

<5.0

 

 

Zr

 

343.823

 

<5.0

 

Nd

401.225 <5.0  

 

Ag

328.068 <3.0
Sm 360.946

 

<10.0

 

 

Sr

 

407.771

<1.0

 

Eu

 

381.967

 

<1.0

  Au

 

242.795

<5.0

 

Gd

 

342.247

<10.0   Pt 265.945

 

<5.0

 

Tb

 

350.917

 

<3.0

 

 

Pd

 

340.458

<5.0
Dy 353.170 <3.0  

 

Ir

 

224.268

<10.0
Ho

 

345.600

 

<3.0

 

 

Rh

343.489

 

<10.0

 

Er

 

337.271

 

<3.0

 

 

Ru

 

240.272

 

<5.0

Tm

 

313.126

 

<3.0

  Ba

 

455.403

 

<1.0

Yb

 

369.419

 

<1.0

  As

 

228.812

≤15

 

Lu

261.541 <3.0  

 

Sb

206.833 ≤15
Y 371.030 <1.0  

 

Bi

223.061 ≤10
Sc 335.373

 

<1.0

 

 

Hg

253.652

 

≤15

Ta

 

226.230

<5.0  

 

Pb

220.353 ≤15

 

Nb

313.340

 

<5.0

  Ga 294.364 ≤10
Mn

 

257.610

 

<3.0

 

 

Se

203.985 ≤10

 

Mg

 

279.553

 

<1.0

  Sn

 

242.949

≤20

 

B

 

249.773

 

<10.0

 

 

Te

214.281

 

≤10

Zn 213.856 <3.0  

 

Ta

226.230 ≤5.0

 

Co

228.616

 

<3.0

  Th 283.730

 

≤10

Si

 

251.611

<10.0  

 

Tl

276.787 ≤30

 

Ni

 

232.003

<5.0   Re 227.525 ≤5视频中心

 

Cd

 

226.502

<3.0   Ge

 

209.426

≤15

 

Fe

239.562

 

<3.0

 

 

Os

225.585 ≤1

 

Ca

 

393.366

 

<1.0

 

 

W

207.911 ≤10

 

Mo

 

281.615

<5.0   Cu

 

324.754

 

<3.0

V 310.230 <5.0  

 

Li

670.784

 

≤3

 

Be

313.041 <1.0   Na 588.995 ≤20
Ti

 

334.941

<3.0  

 

K

 

766.490

≤60

 

 

 

Silicon Industry ICP-MS6880 Icp Mass Spectrometer For Laboratory 1

 

 

 

 

Silicon Industry ICP-MS6880 Icp Mass Spectrometer For Laboratory 2

 

Silicon Industry ICP-MS6880 Icp Mass Spectrometer For Laboratory 3