Product Details

Place of Origin: China

Brand Name: Macylab

Certification: CE,FCC,FDA,ROHS,9001

Model Number: AA-1800C

Payment & Shipping Terms

Minimum Order Quantity: 1pcs

Price: USD8364-USD10300/Set

Packaging Details: Waterproof paper then Carton

Delivery Time: within 7 days

Payment Terms: Western Union, MoneyGram, T/T, L/C

Supply Ability: 5000set/M

Get Best Price
Highlight:

macy lab spectrophotometer aas

,

6 lamps spectrophotometer aas

,

manual turret aas spectrophotometer

Product Name:
AA-1800C
Key Words:
Single Flame System Automatically Peak Find,a Key Opticaloptimization Function
Light Source:
≤6 Lamps Automatic Turret, Automatic Alignment
Power Supply:
110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current:
Pulsed Power Supply
Optical System:
Large 1800 /mm Grating Ruling, Full Closed Optical System
Wavelength Accuracy:
≤0.15nm
Wavelength Repeatability:
±0.1nm
Pectral Bandwidth:
0.1nm、0.2nm、0.4nm、1.0nm、2.0nm (5 Steps With Automatic Changeover)
Baseline Stability:
≤±0.002A/30 Min (Static) ≤±0.005A/30min (Dynamic)
Product Name:
AA-1800C
Key Words:
Single Flame System Automatically Peak Find,a Key Opticaloptimization Function
Light Source:
≤6 Lamps Automatic Turret, Automatic Alignment
Power Supply:
110/220V (+5% ~ -10%), 60/50Hz; 5000VA
Lamp Current:
Pulsed Power Supply
Optical System:
Large 1800 /mm Grating Ruling, Full Closed Optical System
Wavelength Accuracy:
≤0.15nm
Wavelength Repeatability:
±0.1nm
Pectral Bandwidth:
0.1nm、0.2nm、0.4nm、1.0nm、2.0nm (5 Steps With Automatic Changeover)
Baseline Stability:
≤±0.002A/30 Min (Static) ≤±0.005A/30min (Dynamic)
Macy Lab Spectrophotometer Aas 6 Lamps Manual Turret Single Flame

 

Product description:

AA-1800C atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.

 
 
 

 

Main features:

1. High precision automatic optical system

 

1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 6 socket configuration six independent lamp power supply, can be

 

respectively preheating

 

  • Polymer spray chamber

 

Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability

 

  • Titanium burner

 

Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame

 

  • Automatic analysis

 

It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.

 

The light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automaticwavelength scanning and searching peak

 

 

 

  • Software function

 

High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method

 

 

 
 
Technical parameters:
1.1 Optical Splitting System
1.1.1 Grating Line Density:≥1800 bars/mm.
1.1.2 Grating Effective Engraving Area: ≥50 x 50 mm².
1.1.3 Wavelength Coverage:190-900nm.
1.1.4 Spectral Bandwidth :0.1,0.2,0.4,1.0,2.0nm Five gears are automatically adjustable,Automatically set wavelength slit width and energy.
1.1.5 Wavelength Accuracy:≤0.15nm, wavelength repeatability : ±0.1nm.
1.1.6 Baseline Drift :static state≤±0.002A/30min,dynamic state≤±0.005A/30min.
1.1.7 Instrument Spectral Resolution Capability: distinguishable 279.5nm和279.8nm Manganese double line,And when the spectral pass-band is 0.2nm / mm,Peak-valley energy between two lines ≤30%.
1.1.8 Light Source:Six lights automatic switching turret, automatic collimation.
1.1.9 Lamp Current Setting:0-30mA, Automatic computer setting.
1.1.10 *High Performance Power Supply:Built-in high-performance lamp double cathode power supply,For some spectral line interference and unstable elements,Can provide the stability and sensitivity of the machine testing;(Color pages and software screenshots should be provided as evidence)
 
1.2 Flame atomizer
1.2.1 * Characteristic Concentration (Cu):0.015μg/mL/1%.
1.2.2 * Detection Limit (Cu):0.002μg/mL.
1.2.3 * Precision :RSD≤0.5%.
1.2.4 Combustion Head:Metal titanium combustion haed,50mm或100mm Universal combustion head.
1.2.5 Atomizer:Pt-Ir capillary tube,Teflon nozzle,Ceramic impact ball(Can be used for hydrofluoric acid)..Atomizer Chamber :Explosion-proof-type corrosion-resistant material atomization chamber.
1.2.6 Ignition Mode:Microcomputer control, automatic ignition.
1.2.7 Gas Control :Fully automatic gas control system.
1.2.8 Regulatory System :Automatic PC control of flame / graphite furnace automatic switch,And automatically optimized.
1.2.9 safety protection:With the automatic security protection function,anti-backfire automatic gas path protection, acetylene leakage alarm, automatic shutdown system, automatic power off in case of abnormality.
 
1.3 Background Correction :
1.3.1 Flame:Deuterium lamp + self-priming background correction:Correction of the 1A background.
1.4 Data Processing
1.4.1 Measurement Method:Flame method,Hydrogen Method.
1.4.2 Concentration Calculation Method:Standard curve method (1~3 curves),Automatic fitting,standard addition method.
1.4.3 Number Repeated Measurements:1-99 times, calculate the mean value, give the standard deviation and the relative standard deviation.
 
The Factory:
 
Macy Lab Spectrophotometer Aas 6 Lamps Manual Turret Single Flame 0

Macy Lab Spectrophotometer Aas 6 Lamps Manual Turret Single Flame 1Macy Lab Spectrophotometer Aas 6 Lamps Manual Turret Single Flame 2

FAQ
 

Q1. Are you a factory or a trading company?
We are a factory.

Q2. What's the MOQ ?
(1). Normally, MOQ is 1 piece. The quantity is depending on the clients' needs.
(2). If there is no stock, the general MOQ is in big difference due to the Different products. But the quantity still can be negotiated.
Q3. What is your principle for the samples ?
No free samples. But we provide 1piece as a sample order for all items.
Q4.Which payment can be acceptable ?
We could accept the payment by T/T, Paypal, Western Union,L/C, etc.
Q5. How about the lead time?
If no stocks, it takes 7 to 15 working days to manufacture after receiving the advance payment. If in stock, 2-4 working days are possible. But it depends on the exact products and quantity.
Q6. What certificates will be offered?
CE and ISO are certified for most products. Always high quality is offered to avoid any defective products. Also, protective packaging is offered to avoid destroy during delivery.
Q7. What language is offered?
Pure English for the operation panel, display and manuals. Installation & operation videos will be provided as a guidance if necessary.
 
Exhibition:
 
Macy Lab Spectrophotometer Aas 6 Lamps Manual Turret Single Flame 3
 
Our Company:
Macy Lab Spectrophotometer Aas 6 Lamps Manual Turret Single Flame 4
 
The Factory:
 
Macy Lab Spectrophotometer Aas 6 Lamps Manual Turret Single Flame 5
 
Macy Lab Spectrophotometer Aas 6 Lamps Manual Turret Single Flame 6