Send Message
products
products
Home > products > Laboratory Spectrophotometer > Macylab Atomic Absorption Laboratory Spectrophotometer Eight Lights Flame Graphite Furnace Integrated Machine

Macylab Atomic Absorption Laboratory Spectrophotometer Eight Lights Flame Graphite Furnace Integrated Machine

Product Details

Place of Origin: China

Brand Name: Macylab

Certification: ROSH, FCC, CE, ISO9001

Model Number: AA-1800EL

Payment & Shipping Terms

Minimum Order Quantity: 1pc

Price: 39255$

Packaging Details: Cartons And Wooden Cases

Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability: 1000pc

Get Best Price
Highlight:

aa-1800el laboratory spectrophotometer

,

atomic absorption laboratory spectrophotometer

,

macylab spectrometer lab

Product Name:
Macylab Atomic Absorption Laboratory Spectrophotometer Eight Lights Flame Graphite Furnace Integrated Machine
Keyword:
Laboratory Spectrophotometer
Gas Control:
Mass Flowmeter, Automatic Microcomputer Control System
Safety Protection:
Japan Hamamatsu Infrared Alarm, With Automatic Safety Protection Function, Anti-tempering Automatic Gas Path Protection, Acetylene Leakage Alarm, Automatic Shutdown System, Abnormal Automatic Power Off.
Piping Module:
The Machine Is Made Of Sealed Stainless Steel Pipes, Which Need Not Be Replaced For Life To Avoid Aging Of Plastic Pipes
Adjustable Mounting Seat For Cathode Lamp:
Accurate Positioning, Convenient Installation
Product Name:
Macylab Atomic Absorption Laboratory Spectrophotometer Eight Lights Flame Graphite Furnace Integrated Machine
Keyword:
Laboratory Spectrophotometer
Gas Control:
Mass Flowmeter, Automatic Microcomputer Control System
Safety Protection:
Japan Hamamatsu Infrared Alarm, With Automatic Safety Protection Function, Anti-tempering Automatic Gas Path Protection, Acetylene Leakage Alarm, Automatic Shutdown System, Abnormal Automatic Power Off.
Piping Module:
The Machine Is Made Of Sealed Stainless Steel Pipes, Which Need Not Be Replaced For Life To Avoid Aging Of Plastic Pipes
Adjustable Mounting Seat For Cathode Lamp:
Accurate Positioning, Convenient Installation
Macylab Atomic Absorption Laboratory Spectrophotometer Eight Lights Flame Graphite Furnace Integrated Machine

Macylab Atomic Absorption Laboratory Spectrophotometer Eight Lights Flame Graphite Furnace Integrated Machine

Product Description

AA-1800EL atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.
AA-1800EL atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.

 

Technical parameters

 

 

Model

AA-1800EL

Light Source

≤8 lamps automatic turret, automatic alignment

Power Supply

110/220V (+5% ~ -10%), 60/50Hz; 5000VA

Lamp Current

pulsed power supply

Optical System

large 1800 /mm grating ruling, full closed optical system

Wavelength Range

185nm-900nm

Wavelength Accuracy

±0.15nm

Wavelength Repeatability

<0.10nm

Spectral Bandwidth

0.1,0.2,0.4,0.7,1.0,1.4,2.0nm(7 steps with automatic changeover)

Baseline Stability

≤±0.002A/30 min (Static) ≤±0.004A/30min (Dynamic)

 

Flame Analytical System

Detector

Imported Photomultiplier Tube

Burner Head

Full Titanium Combustion Head, 50mm Or 100mm Generalcombustion Head

Atomization Chamber

Polymer Explosion-proof Spray Chamber

Nebulizer

Atomizer Efficient Glass Atomizer, Can Also Be Customized

Ignition Type

Microcomputer Control, Automatic Ignition

Gas Control

Automatic Gas Control System

Detection Limits(Cu)

0.002μg/mL

Precision

RSD≤0.5%

 

Graphite Furnace Analytical System

 

Heating Mode Vertical Heating
Temperature Control Method Vertical Optical Temprature Monitoring Graphite Tube Wall Temperature
Temperature Range Room Temperature To 3000ºc
The Program Automatic Temprature Control Up To 20 Order
Temprature Control The Furnace Enriched Up To 20 Times
Characteristics Volume 0.4*10-12g(cd)
Detection Limit 0.4*10-12g(cd)

Precision

RSD≤2%
The Cooling Water Can Choose Cooling Water Circulation System

Safety

The Graphite Tube Damage, Water Flow Air Pressure And Other Alarmtemperature Overheating Protection

Macylab Atomic Absorption Laboratory Spectrophotometer Eight Lights Flame Graphite Furnace Integrated Machine 0

Main features

 
Total reflection achromatic optical system
The dispersion rate is 1800 lines/mm grating, a new type of self-collimating monochromator, all lenses are quartz-coated, the wide detection range and optical stability ensure the accuracy of analysis, and the blaze wavelength is 230nm grating spectroscopic system.
Eight lamp sockets
One lamp works, up to seven lamps can be preheated, which saves lamp replacement and preheating time, and makes element measurement faster and more convenient.
Full automation
The instrument adopts a fully automatic design. Except for the power switch of the main engine, the functions of the lamp frame control, wavelength scanning, slit adjustment and two-dimensional moving platform of the instrument are all controlled by software.
Background correction system
It has two background correction modes: deuterium lamp and self-absorption. When the background signal is 1A, the ability to deduct the background is more than 60 times.
Analysis software with independent intellectual property rights, complete functions and powerful performance
The user-friendly operation interface makes your operation as easy as the palm of your hand. You can switch between Chinese and English Windows style software interfaces, automatic qualitative and quantitative analysis, automatic calculation of element content, and automatic generation of test reports.


Characteristics of flame system
Polymer atomization chamber
Polymer material anti-corrosion spray chamber, acid and alkali resistance, including hydrofluoric acid, whether it is organic or inorganic solution can get better sensitivity and stability;
Titanium burners
Titanium burner, optional 50mm and 100mm burner, air-cooled premixed type, corrosion resistance, high salt resistance, greatly improving the efficiency of flame and the accuracy of flame analysis;
High-precision anti-clogging atomizer
Patented atomizer, high atomization efficiency, easy maintenance and replacement.
The mass flow controller realizes the acetylene flow control
The mass flow controller precisely controls the acetylene flow with an accuracy of 1ml/min, and dynamically monitors the flow, which is easy to use, safe and reliable.
More safety protection measures to make sample analysis more secure and reliable
Use high-sensitivity detectors to monitor acetylene leakage in real time;
Adopt high-precision pressure sensor to monitor acetylene pressure in real time;
Adopt high-precision pressure sensor to monitor the air pressure of acetylene pressure;
Adopt micro switch and fireproof latch to monitor the state of the combustion head;
Adopt photodiode to monitor the flame state in real time;


Features of graphite furnace system
Integrated design
The graphite furnace power supply and atomic absorption host are located in one instrument, which shortens the cable length, reduces the electromagnetic interference of the graphite furnace power supply to the outside world, and improves the heating efficiency of the graphite tube.
The graphite furnace has high temperature control accuracy and fast heating rate
Using high-power transformers, micro-resistance cables and light-controlled heating methods, and with software and hardware temperature correction systems, the temperature control accuracy in high temperature segments can reach ±1%.
More safety protection measures to make sample analysis more secure and reliable
The cooling water of graphite furnace has real-time monitoring and protection of flow;
Monitoring of carrier gas pressure by pressure sensor
Graphite furnace temperature monitoring by photodiode
Automatic carrier gas flow control
The gas inside and outside the graphite furnace are all automatically controlled by the computer according to the software heating process.
150-position rotary graphite furnace automatic sampler
Polar coordinate turntable graphite furnace automatic sampler, high positioning accuracy, stable and reliable operation, easy to use and maintain.

 

Our Advantages

 
Quality
1. Our products have good quality and very positive reputations in the market.
2. Customers are very happy with them and have a lot of good comments about our intruments and service.
Delivery Time
1. We can get them ready 3-5 days after order confirmation for small orders.
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support
1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online training in our factory.
3. We can have video conference at any time.
Aftersales Support
1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time
One year and extendable

 

Our Company
Double Beam Touch Screen Vis UV Visible Spectrophotometer for LabMacylab Atomic Absorption Laboratory Spectrophotometer Eight Lights Flame Graphite Furnace Integrated Machine 2

Please Contact Us