Product Details
Place of Origin: CHINA
Brand Name: Macylab
Certification: ALL OF MADE IN CHINA
Model Number: AA-1800
Payment & Shipping Terms
Minimum Order Quantity: 1
Price: TALK ABOUT IT
Packaging Details: PE film then put into wooden carton
Delivery Time: Within 5 days
Payment Terms: Western Union, MoneyGram, T/T, L/C, D/A
Supply Ability: 120SET/DAY
Model: |
AA-1800F |
Wavelength Range: |
190nm-900nm |
Light Source: |
≤3 Lamps Automatic Turret, Automatic Alignment |
Power Supply: |
110/220V (+5% ~ -10%), 60/50Hz; 5000VA |
Lamp Current: |
Pulsed Power Supply |
Optical System: |
Large 1800 /mm Grating Ruling, Full Closed Optical System |
Model: |
AA-1800F |
Wavelength Range: |
190nm-900nm |
Light Source: |
≤3 Lamps Automatic Turret, Automatic Alignment |
Power Supply: |
110/220V (+5% ~ -10%), 60/50Hz; 5000VA |
Lamp Current: |
Pulsed Power Supply |
Optical System: |
Large 1800 /mm Grating Ruling, Full Closed Optical System |
AA-1800F atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.
Mainframe
|
||
Model
|
:
|
AA-1800F
|
Light Source
|
:
|
≤3 lamps automatic turret, automatic alignment
|
Power Supply
|
:
|
110/220V (+5% ~ -10%), 60/50Hz; 5000VA
|
Lamp Current
|
:
|
pulsed power supply
|
Optical System
|
:
|
large 1800 /mm grating ruling, full closed optical system
|
Wavelength Range
|
:
|
190nm-900nm
|
Automatically peak find,a key opticaloptimization function
|
||
Wavelength Accuracy
|
:
|
≤0.15nm
|
Wavelength Repeatability
|
:
|
±0.1nm
|
Spectral Bandwidth
|
:
|
0.1nm,0.2nm,0.4nm,1.0nm,2.0nm
|
(5 steps with automatic changeover)
|
||
Baseline Stability
|
:
|
≤±0.002A/30 min (Static)
|
≤±0.005A/30min (Dynamic)
|
||
Absorbance Range
|
:
|
0-4A
|
Flame Analytical System
|
||
Detector
|
:
|
imported photomultiplier tube
|
Burner Head
|
:
|
full titanium combustion head, 50mm or 100mm generalcombustion head
|
Atomization Chamber
|
:
|
polymer explosion-proof spray chamber
|
Nebulizer
|
:
|
atomizer efficient glass atomizer, can also be customized
|
Ignition Type
|
:
|
microcomputer control, automatic ignition
|
Gas Control
|
:
|
automatic gas control system
|
Detection Limits(Cu)
|
:
|
0.002μg/mL
|
Precision
|
:
|
RSD≤0.5%
|