Light Source: | 8 Lamps Automatic Turret, Automatic Alignment | 10/220V (+5% ~ -10%), 60/50Hz; 5000VA: | 110/220V (+5% ~ -10%), 60/50Hz; 5000VA |
---|---|---|---|
Wavelength Range: | 185nm-900nm | Spectral Bandwidth: | 0.1、0.2、0.4、0.7、1.0、1.4、2.0nm |
Baseline Stability: | ≤±0.002A/30 Min (Static) | Absorbance Range: | 0-4A |
Wavelength Accuarcy: | Plus Or Minus 2.0nm | ||
High Light: | 8 lamp flame spectrophotometer,macylab flame spectrophotometer |
AA-1800EL flame/graphite furnace integrated atomic absorption spectrophotometer is a Macylab solely R&D, manufacturing and exclusively selling high-performance, high-reliability spectroscopic instrument, integrated with both flame and graphite furnace atomizer, by use of a computer for the instrument control and data processing through USB 2.0 standard port. This instrument is designed with a tandem optical path structure, the switching between the flame and graphite furnace mode is free of mechanical operation, thus avoid the position deviation caused by mechanical switching, therefore, this instrument is working stably and reliably.
Mainframe
|
||
Model
|
:
|
AA-1800EL
|
Light Source
|
:
|
≤8 lamps automatic turret, automatic alignment
|
Power Supply
|
:
|
110/220V (+5% ~ -10%), 60/50Hz; 5000VA
|
Lamp Current
|
:
|
pulsed power supply
|
Optical System
|
:
|
large 1800 /mm grating ruling, full closed optical system
|
Wavelength Range
|
:
|
190nm-900nm
|
Automatically peak find,a key opticaloptimization function
|
||
Wavelength Accuracy
|
:
|
≤0.15nm
|
Wavelength Repeatability
|
:
|
±0.1nm
|
Spectral Bandwidth
|
:
|
0.1nm,0.2nm,0.4nm,1.0nm,2.0nm
|
(5 steps with automatic changeover)
|
||
Baseline Stability
|
:
|
≤±0.002A/30 min (Static)
|
≤±0.005A/30min (Dynamic)
|
||
Absorbance Range
|
:
|
0-4A
|
Flame Analytical System
|
||
Detector
|
:
|
imported photomultiplier tube
|
Burner Head
|
:
|
full titanium combustion head, 50mm or 100mm generalcombustion head
|
Atomization Chamber
|
:
|
polymer explosion-proof spray chamber
|
Nebulizer
|
:
|
atomizer efficient glass atomizer, can also be customized
|
Ignition Type
|
:
|
microcomputer control, automatic ignition
|
Gas Control
|
:
|
automatic gas control system
|
Detection Limits(Cu)
|
:
|
0.002μg/mL
|
Precision
|
:
|
RSD≤0.5%
|
Contact Person: MacylabSunny
Tel: +8618801377704
UV Laboratory Spectrophotometer Oil acid value with universal parallel interface
Nitrite Laboratory Spectrophotometer Ammonia for drug testing Special UV-1700S
Heavy Metal Detection Laboratory Spectrophotometer Total number of bacteria
Salinity Double Beam Ultraviolet Spectrophotometer For Food Testing
Industrial Inspection Chloroform UV-VIS Spectrometry , Portable Spectrophotometer
Oil peroxide value Double Beam UV Visible Spectrophotometer Ozone
Hexavalent chromium Single Beam Spectrophotometer Indigo UV Photometer
Sulfate Minerals single and double beam spectrophotometer 6 inch LCD display
Soluble iron Single Beam Ultraviolet Visible Spectroscopy For Atmosphere