Product Details

Place of Origin: China

Brand Name: macylab

Certification: ROSH, FCC, CE, ISO9001

Model Number: AA-1800H

Payment & Shipping Terms

Minimum Order Quantity: 1pc

Price: 13210$

Packaging Details: Wooden cases and cartons

Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability: 1000pc

Get Best Price
Highlight:

lab graphite furnace atomic absorption spectrometer

,

high precision atomic absorption spectrophotometer

,

macylab graphite furnace atomic absorption spectrometer

Product Name:
Macylab High Precision Flame And Graphite Furnace Atomic Absorption Spectrometer Six Lamps For Lab
Keyword:
Atomic Absorption Spectrometer
Method Of Measurement:
Flame Method, Graphite Furnace Method, Hydride - Atomic Absorption Method
Gas Control:
Automatic Gas Control System
Temperature Range:
Room Temperature To 3000 Degrees Celsius
The Cooling Water:
Optional Cooling Water Circulation System
Product Name:
Macylab High Precision Flame And Graphite Furnace Atomic Absorption Spectrometer Six Lamps For Lab
Keyword:
Atomic Absorption Spectrometer
Method Of Measurement:
Flame Method, Graphite Furnace Method, Hydride - Atomic Absorption Method
Gas Control:
Automatic Gas Control System
Temperature Range:
Room Temperature To 3000 Degrees Celsius
The Cooling Water:
Optional Cooling Water Circulation System
Flame And Graphite Furnace Atomic Absorption Spectrometer Six Lamps For Lab

Macylab High Precision Flame And Graphite Furnace Atomic Absorption Spectrometer Six Lamps For Lab

Product Introduction

Aa-1800 Atomic Absorption Spectrometer Is Jointly Developed And Completed By Industry Experts And Domestic Well-known Universities, With Decades Of Experience In The Development And Application Of Spectral Instruments. The Products Include Flame, Graphite Furnace And Hydride Generation System, Can Be Configured With A Variety Of Accessories, Flexible Configuration Scheme To Meet The Needs Of Different Levels Of Customers. Aa-1800 Aas Can Be Used For Complex Sample Analysis, And Multiple Analysis Methods Can Be Automatically Switched, So That No One Can Fully Automatic Analysis.

Aa-1800 Atomic Absorption Spectrometer Is Widely Used In Scientific Research, Quality Inspection, Disease Control, Environmental Protection, Metallurgy, Agriculture, Forestry, Chemical And Other Industries, Innovative Software And Hardware Design To Ensure The Accuracy Of Sample Analysis, Safety, Ease Of Use, Simple And Convenient Instrument Maintenance.

 

Flame And Graphite Furnace Atomic Absorption Spectrometer Six Lamps For Lab 0

Technical parameters

Light source ≤6 Hollow cathode lamps Automatic switching
Wavelength range 190-900nm
Spectral bandwidth 0.1,0.2,0.4,,1.0,2.0nm (automatic adjustable)
Wavelength accuracy ≤0.15nm
Wavelength repeatability ±0.1nm
Baseline stability ≤±0.002A/30 minutes( static) ≤±0.005A/30 minutes.(dynamic)
Power  

The main features

 

High precision fully automated optical system

Large AREA GRATING WITH a DISPERSION rate of 1800 lines/mm, new autocollimating MONOCHROMATor, ALL lenses are quartz coated, wide detection range and optical stability ensure accurate analysis. Automatic 6 lamp holder equipped with 6 independent lamp power supply, can be preheated respectively;

 

High polymer atomizing chamber

High molecular material corrosion resistance atomization chamber, acid and alkali resistance, including hydrofluoric acid, whether organic or inorganic solution can get better sensitivity and stability;

 

Titanium burner

Titanium burner, optional 50mm and 100mm burners, air-cooled premix-type, corrosion resistance, high salt resistance, greatly improve the efficiency of the flame and the accuracy of flame analysis;

 

Fully automated analysis

Can automatically complete safe ignition, extinguishing and switching, reliable structure, low failure rate, so as to ensure the sensitivity and reproducibility of flame method.

 

High performance hollow cathode lamp can be directly used to improve the sensitivity of flame analysis, automatically adjust the power supply parameters and beam position, automatic wavelength scanning and searching for wave peaks;

 

Graphite furnace temperature control

Double temperature control of internal and external gas, 20 order linear or nonlinear heating, to ensure that the element to be measured has better sensitivity; The enrichment and concentration in the furnace can reach 20 times, and the inner wall temperature of the graphite tube can be monitored by longitudinal optical control, and the highest temperature can be raised to 3000℃/s.

 

High technology index

AA-1800 atomic absorption spectrometer element test sensitivity reached the industry advanced level, sensitivity ≤0.015μg/mL/1%; The baseline drift was less than 0.003Abs/30m, and the stability was better than 0.005Abs/4h.

 

Background correction system

Using deuterium hollow cathode lamp and self-absorbing button background for background correction, the interference of molecular absorption in low content measurement is eliminated, the emission noise of deuterium lamp is reduced, the service life is prolonged, and the lamp has good stability. When the background signal of deuterium lamp is 1A, the capacity of background deduction is more than 50 times.

 

Intelligent analysis

Intelligence is very strong, humanized design, flame and graphite furnace atomizer automatic switch, graphite furnace atomizer automatic optimization, automatic setting adjustment flame height, automatic ignition, automatic optimization of horizontal position, automatic system automatic setting gas flow. In case of power failure, misoperation, acetylene leakage, the system will automatically start the safety protection function;

 

Automatic sampler

Integrated design with graphite furnace, using high-precision syringe, the minimum can be 0.5μl sample, with intelligent online dilution and concentration function.

 

Software functions

 

Power of function

Highly intelligent software, powerful, friendly Chinese operation interface. Automatic instrument and additional control, automatic optimization, automatic dilution; Mouse operation, automatically set menu data and correction method;

Measurement data can be dynamically displayed. The standard curve can be fitted automatically.

Accurate sample measurement: use the wizard way to set the sample, convenient and fast;

Sensitivity correction function: make the measurement result more accurate;

 

Data sharing

Convenient and fast data sharing

Data processing: the data can be edited and saved;

Printouts: reports that provide unielemental and multielemental analysis; Print the measurement results and the conditions of the instrument;

Data export: The data export function enables data sharing with other systems.

 

Flame And Graphite Furnace Atomic Absorption Spectrometer Six Lamps For Lab 1

  Our Advantages

 
Quality 1. Our products have good quality and very positive reputations in the market.
2. Customers are very happy with them and have a lot of good comments about our intruments and service. 
Delivery Time 1. We can get them ready 3-5 days after order confirmation for small orders.
2. For big quantities, need to be confirmed.
3. In most cases, fast delivery is guaranteed.
Technical Support 1. We have service manual. If not, detailed documents or videos will be provided.
2. We can provide online training in our factory.
3. We can have video conference at any time.
Aftersales Support 1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
2. Within warranty, we will solve the problem for you with no charge(except for consumables).
3. You can call, text or email us at any time. We have good English speakers.
Warranty Time One year and extendable

 

Exhibition 

Flame And Graphite Furnace Atomic Absorption Spectrometer Six Lamps For Lab 2

FAQ

 

Q1: Why choose Macy Lab?
A1: Professional manufacturer with more than 10 years experience
Mainly exported to the European and American markets, and we are also involved in other markets.

Q2: Are you a factory or a trading company?
A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

Q3: OEM , ODM acceptable or not?
A3: Absolutely, yes.

Q4: What can i get the price?
A4: Usually we quote within 12 hours after we get your enquiry

Q5:What are your Delivery terms?
A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

Q6: What about the after-sale service?
A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

Q7: What about the M.O.Q?
A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

Q8: Sample order is OK?
A8: Sample order is no problem.

Q9: What' s kind of shipment for customer choosing?
A9: Usually ship by sea, by air.
We can also provide reasonable solutions according to your transportation requirements.

Q10: Are your operation keypad, interface, software and manual in English version?
A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

Q11: What areas and applications can it be used?
Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

Q12: Which payment can be acceptable ?
A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

Q13: What is the delivery time?
A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

Q14: Can I get a sample?
A14: Yes,please contact our staff for more information.

Q15: How about OEM and ODM?
A15: More than 10 years experience in OEM and ODM.

Q16: What kinds of models do you make ?
A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

Q17: What standard accessories are included?
A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

Q18: Is PC software included?
A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

Q19: Why the reading is red and reach its maximum value 3.00Abs?
A19: Probably you use the glass cuvette in UV range.

Q20: Why the wavelength calibration or self checking fail?
A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

Q21: Why is the reading is not as accurate as before?
A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

Q22: Why PC software can not be installed successfully?
A22: Close your anti-virus software on the computer and do it again.

Q23: Why the software can not be connected successfully?
A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

Q24: Can the data transferred to USB or PC?
A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

Q25: Why the Abs value is negative(lower than zero).
A25: Do the blanking or change the reference sample.